ECL-76, ECL-102, ECL-103
7.3
DC-Kit2 with Dometic CA2500/B2200/B1600 Plus
Roof air conditioner:
– Dometic CA2500
– B1600 Plus/B2200
Circuit diagram:
– CA2500: fig. 3, page 5
– B1600 Plus/B2200: fig. 5, page 7
Charging current distributor: ECL-102
Inverter: PerfectPower PP2002
➤ Install inverter remote control C (membrane button) in an easily-accessible place and
connect its cable to the inverter.
Dometic CA2500
➤ Remove the CA2500's outlet panel.
➤ Connect the charging current distributor to the air conditioner using the two-wire uni-
versal connection cable (on/off cable, item no. 4441300124).
➤ Connect the wire sleeves of the universal connection cable to contacts 12 and 13
on the charging current distributor.
➤ A cable leading out provides the connection to the circuit board (fig. s, page 28). Sev-
er this cable and join the resulting cable ends to the universal connection cable.
Dometic B1600 Plus/B2200
I
NOTE
B2200 with a serial number lower than 802200001 must be installed as
described in chapter 7.4.
➤ Remove the B1600 Plus/B2200's outlet panel, if necessary remove the upper cover.
➤ Connect the wire sleeves of the universal connection cable to contacts I5 and I2 on the
charging current distributor.
➤ Join the on/off cable of the B1600 Plus/B2200 (item no. 4441300129) to the plug
connector on the circuit board (fig. r, page 28).
I
NOTE
Guide the on/off cable carefully past the fan.
➤ Connect both the wires on the universal connection cable (4441300124) to the two
wires on the on/off cable of the B1600 Plus/B2200.
EN
Connection
99