ECL-76, ECL-102, ECL-103
7.6
DC-Kit3/DC-Kit5 with Dometic
CA1000/CA2500/B2200/B1600 Plus
 Roof air conditioner:
– CA1000/CA2500
– B1600 Plus/B2200
 Circuit diagram:
– CA1000/CA2500: fig. 8, page 10 (12 V), fig. c, page 15 (24 V)
– B1600 Plus/B2200: fig. 9, page 11 (12 V), fig. d, page 16 (24 V)
 Charging current distributor: ECL-102/ECL-103
 Inverter: SinePower MSI1812T/MSI1824T
➤ Install inverter remote control MCR-9 in an easily-accessible place (jumper closed,
refer to remote control installation manual) and connect its cable to the inverter.
Dometic CA1000
I
NOTE
Observe also the instructions in the scope of delivery of the sensing cable.
➤ Remove the CA1000's outlet panel.
➤ Using the 2-wire on/off cable (sensing cable, item no. 4441300084), connect contacts
I2 and I3 on the ECL-102/ECL-103 to the air conditioner.
➤ Insert the three-pole plug of the sensing cable into the socket (3-pole pin strip socket)
on the control PCB of the air conditioner (fig. o, page 26).
➤ Set the AC/DC switching parameters for the air conditioner to "02" ( installation
manual for the CA1000, "Configuring the system software").
Dometic CA2500
➤ Remove the CA2500's outlet panel.
➤ Connect the charging current distributor to the air conditioner using the 2-wire universal
connection cable (on/off cable, item no. 4441300124).
➤ Connect the wire sleeves of the universal connection cable to contacts 12 and 13
on the charging current distributor.
➤ A cable leading out provides the connection to the circuit board (fig. s, page 28).
Sever this cable and join the resulting cable ends to the universal connection cable.
Dometic B1600 Plus/B2200
I
NOTE
B2200 with a serial number lower than 802200001 must be installed as
described in chapter 7.4.
➤ Remove the B1600 Plus/B2200's outlet panel, if necessary remove the upper cover.
➤ Connect the wire sleeves of the universal connection cable to contacts I5 and I2 on the
charging current distributor.