Dc-Kit1 With Dometic Ca1000; Dc-Kit1 With Dometic Freshjet1100 - Dometic Waeco ECL-76 Instructions De Montage Et De Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Connection
I
NOTE
The remote controls for switching the inverters on and off must be connected
in accordance with the enclosed instructions and the relevant circuit diagram
(see pages fig. 1, page 3 to fig. m, page 25).
7.1

DC-Kit1 with Dometic CA1000

 Roof air conditioner: Dometic CA1000
 Circuit diagram: fig. 1, page 3
 Charging current distributor: ECL-76
 Inverter: PerfectPower PP1002
➤ Install inverter remote control C (membrane button) in an easily-accessible place and
connect its cable to the inverter.
I
NOTE
Observe also the instructions in the scope of delivery of the sensing cable.
➤ Remove the CA1000's outlet panel.
➤ Insert the three-pole plug of the sensing cable into the socket (3-pole pin strip socket)
on the control PCB of the air conditioner (fig. o, page 26).
➤ Link the ECL-76 to the air conditioner using the two-wire on/off cable (sensing cable,
item no. 4441300084).
➤ Set the AC/DC switching parameters for the air conditioner to "02" ( installation
manual for the CA1000, "Configuring the system software").
7.2

DC-Kit1 with Dometic FreshJet1100

 Roof air conditioner: Dometic FreshJet1100
 Circuit diagram: fig. 2, page 4
 Charging current distributor: ECL-76
 Inverter: PerfectPower PP1002
➤ Install inverter remote control C (membrane button) in an easily-accessible place and
connect its cable to the inverter.
I
NOTE
Observe also the instructions in the scope of delivery of the sensing cable.
➤ Remove the FreshJet's outlet panel.
➤ Use the two-wire sensing cable to link the ECL-76 to the 6-pole pin strip socket (item
no. 4441300881) of the air conditioner (fig. p, page 27).
98
ECL-76, ECL-102, ECL-103
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Waeco ecl-102Waeco ecl-103

Table des Matières