Faults
Faults, displays
00:00
E 36
E 38
AA 1
AA 2
No display.
Additional dis-
play symbols are
shown.
Pump does not
start.
Pump making
noises.
26
9 Faults
Cause
Time not set.
Power failure longer than 3 hours.
Electronic fault, module defective.
Temperature sensor defective
Temperature control setting not
DVGW-compliant.
Switch-off time not DVGW-com-
pliant.
Power supply interrupted.
Frequency superimposed when
operating in an industrial environ-
ment or near radio transmitters.
Power supply interrupted, short cir-
cuit or fuses defective.
Timer function has switched off
automatically.
Motor is blocked, e.g. by deposits
from the water circuit.
Motor scraping, e.g. through
deposits from the water circuit.
Running dry, too little water.
Note: If you cannot remedy the fault, contact the trade.
Remedy
Set clock.
Set clock, create secure power supply
if necessary.
Have the motor head replaced by a
specialist > Page 22.
Have the motor head replaced by a
specialist > Page 22.
Set temperature above 55 °C.
Set switch-off time to less than 8
hours.
Restore power supply.
This fault does not affect the pump
function.
Have the power supply checked by a
qualified electrician.
Check the timer function setting
> Page 24.
Have a specialist remove the pump
> Page 22.
The movement of the impeller is
restored by turning it and flushing out
the dirt.
Check the stop valves; they must be
completely open.
WILO AG 01/2007