3.

Safety Distances

The indicated safety distances apply to flammable
materials or materials with flammable parts with a
thermal resistance of R ≤ 6 m²K/W.
For particularly temperature-sensitive materials like
glass, larger distances may be necessary.
Within a radius of 110 cm in front, 80 cm on the right
and 20 cm on the left side of the stove, flammable,
combustible, or heat-sensitive materials (e.g. furni-
ture, wood or plastic panelling, curtains, etc.) are
not allowed to be located in the heat radiating area
of the fire box window (fig. 1).
Outside the radiation area of the fire box window, a
safety distance of 5 cm sideways and 7 cm behind
the stove is to comply to flammable materials (fig.
1). Above the stove, the safety distance of 50 cm to
flammable materials has to be complied with (fig. 2).
No flammable or temperature-sensitive materials
may be present within a radius of 20 cm around the
flue pipe connection (wall or room ceiling).
WARNING!
Flammable flooring materials (e.g., wood,
laminate, carpeting,) must be protected
with a floorplate made of non-combustible
material (e.g., tiles, safety glass, slate, or
sheet steel).
The size of the floorplate must be larg-
er than the base of the stove by at least
50 cm in front and at least 30 cm at the
sides of the stove (fig. 3).
80*
20
110
80*
5*
110
fig. 1
* For highly-insulated components with a thermal
insulation resistance of R ≤ 6 m²K/W, the existing
gaps should be extended to 5 cm.
Abb. 2
11
50
30
50
fig. 3
fig. 3
Dimensions in cm
GB
floor-
plate
45