ORGAPACK OR-V 40 P
4
4.1 OPERATING THE TOOL
a) Sealing
– Place the sealer OR-V 40 P on top of the seal.
– Actuate the lever, the seal is notched.
Do not put your fingers into the sealing area!
Check of seal
To obtain the maximum seal efficiency, the notches
have to be cut properly into the seal. If these notches
are not correctly cut, replace jaws and notcher (see
Chapter 5.1).
b) Turning of sealer unit (see Fig. 1b)
– Disconnect sealer from air supply.
– Loosen four cylinder screws, pos. 50 (see explosion
drawing, page 8).
– Loosen screw, pos. 38, and lever, pos. 12.
0
– Turn sealer unit 90
, and install all parts.
5
5.1 REPLACING JAWS AND NOTCHER
Removal
– Disconnect sealer from air supply.
– Remove two lock washers (2/8) and remove cylinder
screws (2/1).
– Remove two counter sunk screws (2/4) and remove
both side plates (2/3).
– Remove four bolts (2/6) and (2/7). Clean and if necessary
replace jaws (2/2) and notcher (2/5).
Installation
– Install the parts in reverse order.
12
OPERATING INSTRUCTIONS
PREVENTIVE AND CORRECTIVE MAINTENANCE
1b
Fig. 1
8
7
Fig. 2
1
2
3
6
5
4
08.00/WE