steute EX RF 96 ST SW Série Instructions De Montage Et De Câblage page 16

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
Ex RF 96 ST SW***
//
Montage- und Anschlussanleitung / Funk-Universalsender
Mounting and wiring instructions / Wireless universal transmitter
Instructions de montage et de câblage / Emetteur universel sans fil
Istruzioni di montaggio e collegamento / Trasmettitore universale wireless
Instruções de montagem e instalação / Transmissor universal wireless
Инструкция по монтажу и подключению / Универсальный радио-передатчик
English
Technical data Ex RF 96 ST SW***
Applied standards
EN 60947-5-1; EN 6100-6-2;
EN 301 489-1; EN 301 489-3;
EN 300 220-1; EN 300 220-2;
EN 60079-0:2012+A11:2013;
EN IEC 60079-0:2018;
EN 60079-11:2012;
IEC 60079-11:2011
Enclosure
fibreglass-reinforced, shockproof thermo-
plastic (PA 66), self-extinguishing UL 94-V0
Tightening torque
M4 mounting screw enclosure:
max. 1.2 Nm
M2.5 cover screws: approx. 0.45 Nm
Connection
connector M12 x 1, 4-pole
Suitable sensors
Corresponding Ex Wireless inductive sensors
type: Ex RF IS M** nb-ST Xm or approved
intrinsically safe sensors.
Degree of protection
IP20 to IEC/EN 60079-11,
IP67 to IEC/EN 60529
Protocol
SWave®
Ambient temperature
-20°C ... +60°C
Switching frequency
max. 5 Hz
Standby current
215 µA (incl. sensor)
Voltage supply
Ex approved and certified batteries,
manufacturer steute, type: Ex RF BAT 3.6 V,
II 2G Ex ib IIC T4G;
L
II 2D Ex ib IIIC T135° D
L
BVS 18 ATEX E 035 X
IEC Ex BVS 18.0056 X
permissible ambient temperature:
-20°C ... +70°C
Capacity
2.1 Ah (with integrated protective circuit)
Frequency
868.3 MHz (EU) or
915.0 MHz (USA, Canada, Mexico)
Transmission power
<25 mW
Data rate
66 kbps
Channel bandwidth
Ex RF 96 ST SW868: 480 kHz,
Ex RF 96 ST SW915: 550 kHz
Wireless range
max. 450 m outside,
max. 40 m inside
Actuating time
min. 80 ms
Battery life
depending on the switching frequency
100 s approx. 1100 days,
10 s approx. 1000 days,
1 s approx. 500 days
Note
transmission of battery voltage and
switching condition
Ex marking
L
II 2G Ex ib IIC T4 Gb
L
II 2D Ex ib IIIC T135°C Db
BVS 19 ATEX E 009X
Ex ib IIC T4 Gb
Ex ib IIIC T135° Db
IECEx BVS 19.0040X
Technical data Ex Wireless inductive sensors
Ex RF IS M** nb-ST Xm
Applied standards
EN 60947-5-2
Enclosure
brass, nickeled, back cap PVC, black
Connection
coupling M12 x 1, 4-pole
cable length 0.5; 1; 2; 5 or 10 m
Degree of protection
IP67 to IEC/EN 60529
Ambient temperature
-20°C ... +60°C
Ex RF IS M12 nb-ST Xm Switching distance = s n 4 mm;
s a 0 ... 3.24 mm; s r 3.6 ... 4.4 mm
Actuator = steel plate 12 x 12 x 1 mm, FE 360
Tightening torque = 10 Nm
Ex RF IS M18 nb-ST Xm Switching distance = s n 8 mm;
s a 0 ... 6.48 mm; s r 7.2 ... 8.8 mm
Actuator = steel plate 24 x 24 x 1 mm, FE 360
Tightening torque = 25 Nm
Ex RF IS M30 nb-ST Xm Switching distance = s n 15 mm;
s a 0 ... 12.15 mm; s r 13.5 ... 16.5 mm
Actuator = steel plate 45 x 45 x 1 mm, FE 360
Tightening torque = 75 Nm
Hysteresis
approx. 10%
Repeatability
<5%
Type of installation
non-flush
Switching frequency
see Ex RF 96 ST SW***
Correction factors
Steel (St37) = 1; V2A approx. 0,7; Ms approx.
0,5; Al approx. 0,5; Cu approx. 0,4
Actuator
Ex RF IS M12 nb-ST:
steel plate 12 x 12 x 1 mm, FE 360
Ex RF IS M18 nb-ST:
steel plate 24 x 24 x 1 mm, FE 360
Ex RF IS M30 nb-ST:
steel plate 45 x 45 x 1 mm, FE 360
Note
The sensor may only be used in combination
with an Ex RF IS M** nb-ST Xm; 2 mounting
nuts are provided.
Errors and technical changes reserved.
16 / 24

Publicité

Table des Matières
loading

Table des Matières