7. PROGRAMMING

7.7.11 Start Speed in Open and Close Directions

Start Speed function allows switching the Soft-Start in OPEN and CLOSE directi-
ons ON and OFF.
deactivated (Default)
Soft Start active: motor will accelerate gradually until it reaches
standard speed.

7.7.12 Maintenance Counter

Maintenance Counter function allows to set maintenance interval in cycles.
4 seconds pre-flashing of the Flashing Lamp will be a signal the interval is reached.
If PF Function (Pre-Flashing) is active then 4 second pre-flashing will be added
to the set time. To reset counter after maintenance is done, it will be enough to
program the cycles one more time.
no counter (Default)
1000 cycles

8. BATTERY BACKUP

Battery Back-Up Mode (BBU)
Optional 12V, 2.2Ah lead batteries SKU 490EV (optional, not included) can be mounted inside operator housing.
Follow the manual of SKU Nr 490EV for exact installation procedure.
A Flashing lamp (if mounted) will flash 2 seconds every 10 minutes indicating BBU mode and power loss.Control board will switch into stand-by mode with active radio
receiver accepting radio control device commands only. All other accessories and peripheral devices will not be functioning. When in Battery Back-up mode, myQ Smart-
phone Control and wireless myQ devices will be disabled. Full charged battery capacity shall support up to ~20 cycles at a rate of 2 per hour. After 24 hours of BBU mode
the battery shall provide power for 1 complete opening and closing cycle.
Please note that only the specified battery can be use. Use of any other battery leads to loss of warranty and loss of liability of Chamberlain for any related damages
resulting from use of unspecified batteries.
2000 cycles
...
... cycles
20000 cycles
7.8 Factory Default
Factory default function resets control board to the original factory set-ups. All set-
tings, including limit settings, will be erased. LED display will show "E0". Program-
med remote controls will remain learned. If Remote control accessories need to be
erased refer to the respective Radio Controls Programming section of this manual.
no reset (Default)
reset to the factory default settings

7.9 Finish and Exit

To exit the programming phase and save all changes,
move to FE function and press "P" button. The control board will go into Stand-by
mode and is ready to work.
There are also other ways to exit the programming and save settings:
• Press and hold "P" button for 5 seconds
• Wait 3 minutes after the last changes in the programming for automatic exit