EN
®
15
Connect the bottom cable and run it towards the
connections box, insert the blue cable through the
rubber sleeve and secure the supplied terminal,
introducing it in the connections box and placing
it in position X02, then fit a 30 A fuse and secure
with nuts.
Fixing point,
top cable
15
15
Run the cable through the
Pass the cable to position X02 and clamp the terminal
supplied rubber sleeve
15
15
Connection box (+)
Fit the supplied 30A fuse and secure with the nuts
23