Troubleshooting
Alert messages
fig. p A, page 15.
E.g. see
Alert message
Description
!ALERT - Lid open
Lid open more
> 3min
than 3 minutes
!ALERT - Voltage
The device has
low
stopped working
on DC due to low
voltage
The device has
stopped working
on DC due to
abnormally high
voltage >31.5 V
(unlikely event –
for electronics
protection only –
uses same alert
message as low
voltage above)
36
Possible cause
Lid not fully
latched
Internal fault
Insufficient supply
voltage
Battery voltage is
too low
Battery protec-
tion is set too high
Wrong DC supply
voltage
specification
Faulty supply
voltage
Internal fault
Suggested remedy
Check lid latched fully
Call the customer
service.
Check voltage drop
from battery to power
outlet and increase wir-
ing gauge if necessary
Test the battery and
charge as needed
Select a lower battery
protection setting
Ensure DC supply volt-
age specification
matches CFX3 product
rating label
Check DC voltage
supply and repair or
replace if faulty
Call the customer
service.