Connecting eStore
Connect BUS cable and configure
For configuration you need a PC with a USB port and the eStore configurator.
Depending on the installation situation it may be useful to configure and tag each
eStore before installation into the vehicle.
➤ Make sure that eStore is not in storage mode (status LED is blinking).
➤ Plug the USB cable from the PC into the USB port (fig. 1 5, page 3) of the first
(master) eStore.
➤ Configure the master, see chapter "Configuring connected eStores" on
page 20.
➤ Attach the ID label (fig. 6 6, page 4) on the master (fig. 6 1, page 4).
➤ Disconnect the USB cable from the master.
➤ Plug the USB cable from the PC to the USB port of the first slave.
➤ Attach the ID label (fig. 6 3, page 4) on the slave (fig. 6 2, page 4).
➤ Configure the remaining slaves, if necessary.
➤ Connect the eStores with the BUS cables (fig. 6 4, page 4).
8.8
Configuring connected eStores
➤ If necessary, install the ModbusReader "mbreader_setup.exe" from the data CD
to your PC.
➤ Copy the file "eStore_Configuration_utility_FM739.mbc " of the data CD to the
hard disk of the PC .
➤ Open the file "eStore_Configuration_utility_FM739.mbc".
✓ The eStore configurator opens (fig. 7, page 5).
➤ Press CTRL + F or select in the menu "Connection" the command Find COM
(fig. 8 1, page 5).
➤ Select the new port number, in the example COM18 ( fig. 8 2, page 5).
➤ Press CTRL + P or select in the menu "Connection" COM Parameters
(fig. 8 3, page 5).
➤ The window COM Settings opens.
➤ Choose from the list Parity (fig. 8 4, page 5) the value Even.
➤ Click OK (fig. 8 5, page 5).