• Set the day, hour and minute and confirm in each case with
the function key
.
• Confirm your selection with the function key

5. Measuring blood pressure

Positioning cuff
• Bare your left wrist, making sure that the circulation in the
arm is not restricted by any clothes etc. that are too tight.
Position the cuff on the inside of your wrist.
• Fasten the cuff with the Velcro fastening so that the upper
edge of the monitor is positioned approx. 1 cm below the
ball of your thumb.
• The cuff has to be fitted tightly around the wrist but should
not constrict it.
Correct posture
• Rest for approx. 5 minutes before each measurement. Other-
wise there may be divergences.
• You can perform the measurement
while sitting or lying. To carry out a
blood pressure measurement, make
sure you are sitting comfortably with
your arms and back leaning on some-
thing. Do not cross your legs. Place
your feet flat on the ground. Make sure to rest your arm and
move it. Always make sure that the cuff is at heart level.
.
Otherwise significant deviations can occur. Relax your arm
and the palm of your hand.
• In order not to distort the result, it is important to keep still
during the measurement and not talk.
Select memory
Switch on the blood pressure monitor with the
the required memory space by pressing the function key +. You
have two memories (60 memory spaces each) in order to save
the test results of 2 different people separately, or else save
measurements in the morning and evening separately.
Measuring blood pressure
• Put on the cuff as described previously and assume the posi-
tion in which you want to carry out the measurement.
• Using the buttons +, select the user memory 1 or 2. Start the
measurement process by pressing button
ing the display with all digits lighting up, the monitor will
automatically inflate. Following the self-test, during which all
display elements briefly appear, the measurement begins.
During inflation the device already determines measured val-
ues used to estimate the required inflation pressure. If this
pressure is insufficient, the device automatically inflates by
another.
• Then the pressure in the cuff is slowly released and the pulse
is measured.
• When the measurement has been completed, the remain ing
• • • • • • • • • • • • •
air pressure is released very quickly. The pulse, the systolic
and the diastolic blood pressure are displayed.