Description - Hilti PMC 36 Mode D'emploi

Masquer les pouces Voir aussi pour PMC 36:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
Symbols
Read the
Disposal of
operating
power tools or
instructions
appliances and
en
before use.
batteries
together with
household
waste is not
permissible.
On the tool
3R
Laser warning plate in accordance with IEC825 /
EN60825-1:2003

2. Description

2.1 Use of the product as directed
The PMC 36 is a self-leveling combilaser which allows a single person to level, plumb, align and transfer
right angles quickly and accurately. The tool projects two lines (horizontal and vertical) and five points (above,
below, right, left and line intersection). The lines and line intersection point have a range of approx. 10m. All
other points have a range of approx. 30m. Range depends on the brightness of ambient light.
The tool is intended mainly for indoor use.
When the tool is used outdoors, care must be taken to ensure that the conditions correspond to working
indoors. Possible applications are:
Marking the position of partition walls (at right angles and in the vertical plane).
Aligning components to be installed or sections of a structure in three axes.
Checking and transferring right angles.
Transferring measuring marks from the floor to the ceiling.
Observe the information printed in the operating instructions concerning operation, care and maintenance.
Take the influences of the surrounding area into account. Do not use the appliance where there is a risk of fire
or explosion.
To avoid the risk of injury, use only genuine Hilti accessories and additional equipment.
The tool and its ancillary equipment may present hazards when used incorrectly by untrained personnel or
when used not as directed.
Modification of the tool is not permissible.
2.2 Features
The PMC 36 levels itself automatically within a range of 3.5°.
Self-leveling takes only approx. 5 seconds.
The combilaser gives an "Out of self-leveling range" warning when the self-leveling range is exceeded (the
laser beams blink).
14
Printed: 07.07.2013 | Doc-Nr: PUB / 5071411 / 000 / 00
On the tool
C A U T I O N
LASER RADIATION - DO NOT
STARE INTO BEAM
620-690nm/2.45mW max.
CLASS IIIa LASER PRODUCT
Do not stare into the beam.
Laser warning plates for the USA in accordance with
CFR 21 § 1040 (FDA).
Location of identification data on the tool
The type designation and serial number can be found
on the type identification plate on the tool. Make a
note of this data in your operating instructions and
always refer to it when making an enquiry to your
Hilti representative or service department.
Type:
Serial no.:

Publicité

Table des Matières
loading