Redox measurement display (A and B
configuration)
Progrma Menu
Rx Measure
Rx Measure
Setpoint
Rx Measure
Sp Type
Rx Measure
OFA Time
Rx Measure
Alr Band
Rx Measure
Type
pH Plus measurement display (A
configuration)
Progrma Menu
pH plus measure
pH plus measure
Setpoint
pH plus measure
OFA Time
pH plus measure
Alarm
pH plus measure
Type
000013791
Use Enter to access the sub-menus:
Press Enter and the + and - keys to change
the Set Point value (0÷1500 mV).
760mV
Press Enter and the + and - keys to change
the Set Point type.
Low
Press Enter and the + and - keys to set the
OFA time to OFF or from 1 to 240 min. (see
Off
Paragraph 9.5)
Press Enter and the + and - keys to set the
band alarm from 100 to 300 mV.
300mV
Press Enter and the + and - keys to change
the dosing type.
PROP
Use Enter to access the sub-menus:
Press Enter and the + and - keys to modify
the Set Point value which ranges from 0 pH
7.0 pH
to (Set Point pH Minus - 0.4 pH).
Press Enter and the + and - keys to set the
OFA time to OFF or from 1 to 240 min (see
Off
Paragraph 9.5).
Press Enter and the + and - keys to set the
alarm ranging from 0 pH to Set Point - 0.1
6.0pH
pH. This alarm is shown on the display.
Press Enter and the + and - keys to change
the dosing type.
PROP
Rev. 1.0
Settings
 Setpoint
 Sp Type
 OFA time
 Alr Band
Type
 Low
High
 PROP (see Paragraph 9.2).
 ON/OFF (see Paragraph 9.4).
OFF (dosing disabled)
Settings
 Setpoint
 OFA time
 Alarm
Type
 PROP (see Paragraph 9.1).
 ON/OFF (see Paragraph 9.1).
OFF (dosing disabled)