Programming - Seko Pool Basic Pro Evo Manuel D'installation

Ph-/rx/ph+ - ph/rx/flocc
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

The programming menu can be accessed by simultaneously pressing the Cal and Set keys
for at least 3 seconds.
Upon release of the keys the display will show:
Language Display
Progrma Menu
Language
The menu will show a different display according to the chosen configuration:
Configuration A: pH-/Rx/pH+
Configuration B: pH/Rx/Flocc
For further details please see the menu AdvancedConfiguration
To prime the pH-/pH pump, press the UP button for at least 3 seconds and release it to stop
the operation. To prime the pH+/FLOCC pump repeat the same procedure pressing the
DOWN button for at least 3 seconds, for to prime the Redox pump press the UP and DOWN
keys together.
pH Minus measurement display (A
configuration)
Progrma Menu
pH minus measure
pH minus measure
Setpoint
pH minus measure
OFA Time
pH minus measure
Alarm
pH minus measure
Type
000013791

8. PROGRAMMING

Press Enter and the + and – keys to change
the language:
EN
FR, EN, IT, ES, DE
Use Enter to access the sub-menus:
Press Enter and the + and - keys to modify
the Set Point value which ranges from (Set
7.4 pH
Point pH Plus + 0.4 pH) to 14 pH.
Press Enter and the + and - keys to set the
OFA time on OFF or from 1 to 240 min (see
Off
Paragraph 9.5).
Press Enter and the + and - keys to set the
alarm ranging from Set Point + 0.1 pH to 14
8.4pH
pH. This alarm is shown on the display.
Press Enter and the + and - keys to change
the dosing type.
PROP
Rev. 1.0
Settings
Settings
 Setpoint
 OFA time
 Alarm
Type
 PROP (see Paragraph 9.1).
 ON/OFF (see Paragraph 9.3).
OFF (dosing disabled)
11

Hide quick links:

Publicité

Table des Matières
loading