• Then pass the tube into the roller holder guide.
• Turn the roller holder clockwise and accompany the tube up to the right fi tti ng.
• Refi t the peristalti c pump cover.

4.2 Wintering

• During wintering it is recommended to rinse the peristalti c tube using clean water by carrying out
manual priming (see §3.4).
• Then place the roller holder at 6 o'clock to facilitate restarti ng.
• Remove the Redox sensor from its holder and store it in its original bott le, or in a container full of
tap water.
• Close off the sensor holder if necessary.
Always keep the sensor in water and protected from freezing.
5. Troubleshooti ng

5.1 Displays

Message
«Level»
• Protector
empty
• Floater blocked
• Level sensor short circuited.
«OFA Alarm»
First step in the over feed safety
system acti vated (ti me > 75%)
Second step in the over feed safety
system acti vated (ti me = 100%)
«OFA Stop»
Redox sensor measurement test
«OFA Check»
when the «OFA Stop» was acti vated
during a previous fi ltering cycle.
«Flow»
• Filtering stopped
• Incorrect connecti on
«Error»
• Used Buff er soluti on(s)
• Redox sensor dirty
• Defecti ve Redox sensor
«Error
Setti ng error
Parameter»
5.2 Appliance malfuncti ons
Malfuncti on
The appliance
Cable
always shows a va-
connector problem
lue close to 0mV
The appliance
• The Redox sensor connecti on
always shows
cable is damaged
an unsuitable or
• The Redox sensor is worn
constantly unstable
• The Redox sensor cable is too
value
close to an electric cable cau-
sing disturbances
9
Possible causes
product
container
Possible causes
problem
and/or
BNC
• Replace the corrector product container
• Check that the white fl oater on the sucti on cane is in working
order
• Change the sucti on cane
• Press
to stop the alarm
• Check the sensor and/or the pool chlorine level
• Press
to stop the alarm
• Check the sensor and/or the pool chlorine level
• Wait for the end of the procedure (1 hour) then check the
sensor and/or the pool chlorine level.
• Start and/or check the fi ltering
• Check the electric connecti ons
• Replace the buff er soluti on(s)
• Clean the Redox sensor using a 10% HCl soluti on
• Replace the Redox sensor
• Press
to cancel the fault
• Replace the electronic card
• Check that the connecti on between the sensor and the
control box is not short circuited (between the cable's
central core and the external shielding)
• Check that there is no humidity and/or condensati on at
the BNC connector level
• Check the cable and/or the BNC connector
• Reduce the distance between the appliance and the sen-
sor
• Replace the Redox sensor
• Place the sensor in a more suitable locati on (see §2.2.1)
Soluti ons
Soluti ons
H0435000.A - EN - 2013-11