• The Redox sensor must be installed at more than 30 cm in front or aft er a piping bend. Use the opti onal POD kit
if necessary. Failing to follow this positi oning can lead to incorrect or unstable measurements.
• The ti p of the Redox sensor must not be in contact with the pipe.
• Never install a Redox sensor before the fi ltering pump or between the pump and the fi lter. This would cause
random readings and a shortened service life.
2.2.2 Injecti on point locati on
• Injecti on must be the last element on the pool circuit, before a pH corrector injecti on and aft er the heati ng system.
2.2.3 Sensor and injecti on point installati on
• There must be at least 0.6 metres between the sensor and the injecti on point. If this is not possible, use the POD kit
available as an opti on or a check valve.
• Fixture collars (or the POD kit) must be installed on rigid Ø50 PVC pipes. A Ø63 adapter is available as an opti on.
• The POD kit is recommended if a pH regulati on has also been installed.
• Maximum pressure must not exceed 1.5 bar.
• Drill a hole with a diameter between 16 and 22 mm on the pipe at the selected locati ons for the pH sensor and the
injecti on point.
• Then install the fi xture collars.
• Use Tefl on tape to make sure the threads on the sensor holder, the injecti on valve and its adapter are waterti ght.
2.3 Electric connecti ons
• Install the control box on a rigid, verti cal surface in an easy to access locati on using the supplied fi xture kit.
• Connect the power supply cable to a 230Vac mains outlet.
• Connected the bared wire to couple the fi ltering pump to the fi ltering pump 230Vac contactor using a relay to avoid any
voltage returns when the pump is stopped.
Only power on the appliance once all connecti ons (electric and hydraulic) are complete.

3. Use

3.1 Control box presentati on
5
Acti vati ng the sensor calibrati on mode (press for 5 seconds)
Validate a choice in the «Setti ngs» menu
Cancel the «OFA» over feed safety system
View the set point value (press for 5 seconds)
Exit the «Setti ngs» menu
Scroll up or down through the «Setti ngs» menu
Acti vate the «Priming» functi on (press the top butt on for a long ti me)
Acti vate «Boost» mode (press both butt ons at the same ti me)
0-1
General switch to power the appliance on and off
H0435000.A - EN - 2013-11