Festo VPEV-1/8-M12 Notice D'utilisation page 19

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
VPEV-1/8-M12
Correcting the switching point:
8. Repeat the following steps until the upper and lower switching vacuums have
been set:
– first set the lower switching vacuum with adjusting screw 7
– then set the upper switching vacuum with adjusting bolt 5.
In this way, you can specify step-by-step the switching point and the hystere-
sis.
9. Replace and fasten the protective cap 6.
Functional test:
S
Apply AC or DC current to the VPEV-... (maximum voltage Vb = 48 V AC/DC).
6
Operation
Please note
S Please note that fluctuations in the medium temperature will have a minor
effect on the switching point.
At medium temperatures below 1 °C:
Please note
S Avoid the dew point being reached.
The diaphragm will freeze up and become stiff at temperatures below the
dew point. This will affect the switching values set on the vacuum switch.
The dew point can be reduced considerably by the application of dried com-
pressed air.
Festo 0007NH– English
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

192 489

Table des Matières