Camera Setup - Dedicated Micros Eco4 Guide D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
Important information regarding Protected Images.
There is a percentage indication of the amount of images that are currently
protected on the hard disk. It is important to remember that the protected images
will remain on the hard disk and will not be overwritten until they are manually
removed.
Protected images reduce the amount of space you have for normal recording. For
example, if 50% of the images are protected, this effectively means you only have
half the disk available for normal recording, so recording settings that should
normally give you 30 days would only allow 15 days of recording.

Camera Setup

Camera Set-Up
Title
Input termination
Camera type
Alarm input/Polarity
Colour adjust
Contrast adjust
Camera video input
Title
Each camera title can be up to 12 characters long.
Input termination
The input termination does not auto detect by default, the termination must be set
manually On (default) or Off. The termination must be set to Off if the camera is
looped through to other equipment.
Camera type
Colour and monochrome cameras are detected automatically, allowing colour/mono
switching cameras to be connected. The camera type can be manually configured
as Colour or Mono if necessary.
Alarm input/Polarity
Select whether the alarm connected is Normally open (default),
Normally closed, or Off.
Colour adjust
When the colour bar is selected, press
Note: this option is not displayed if the camera is set as monochrome.
Contrast adjust
When the contrast bar is selected, press down to reduce, and up to increase
the contrast.
Camera video input
This option is only displayed when a camera has failed or is offline. Select
disconnect whilst the camera is offline to prevent the camera fail message and
alarm being triggered.
Tip: This menu can be entered directly by pressing and holding a camera key.
CAMERA 1
Auto detect
Off, On
Auto detect
Off, On
Normally open
Normally closed, Off
Connected
Disconnected
to reduce, and
to increase the colour.