end of the surface as higher by the same amount of bars, plus or minus one
bar. Taking the same example, the display should now show the center bar
with two bars on top on the right side of the display and two bars on the bot-
tom on the left side of the display (Figure 8 below).
If this is not the case, the level is out of calibration and should be recalibrate
before being used.
Note: This process of turning the level end for end and comparing the
two indications relative to the surface is applicable to all levels, including bub-
ble levels.
Figure 6: Checking the LaserVision in One Direction
Figure 7: Turning the LaserVision End-for-End
Figure 8: Checking the LaserVision in the Other Direction
C C a a l l i i b b r r a a t t i i n n g g t t h h e e L L a a s s e e r r V V i i s s i i o o n n
The LaserVision's level module can be re-calibrated at any time to the original fac-
tory specifications to ensure precision.