CCW
Figure 13: Aligning the Laser Spot
Finding Level and Plumb
The LaserVision features four segmented bars which indicate the angular
proximity of the LaserVision to level or plumb. (See Table I for Working Precision
Display.) The arrows displayed on both sides of the segment bars further indicate
which way to rotate the LaserVision to reach level or plumb. When level or plumb
is found, the LCD indicates a single bar and sounds an audio tone (unless the
sound has been turned off).
Working Precision Display:
Deviation from Level or Plumb: Maximum (Typical)
LCD
Segment
Center Bar
1st Bar
from Center
2nd Bar
from Center
3rd Bar
from Center
Using the Laser
• Turn on the LaserVision and adjust to level or plumb.
• Push the laser power button located on the laser end cap (Figure 5, page 5).
When the laser is on, the button glows red.
• Point the LaserVision in the desired direction.
• Then mark the position of the laser spot.
NOTE: 1. Since the laser spot gets larger as it gets further from the LaserVision,
to ensure maximum accuracy, be sure to always mark the center of the spot.
2. The laser spot is projected from the center of the laser end cap and
is one inch from either top or bottom surface of the level. Be sure to
compensate for this one-inch difference.
Inches/100 Feet
0.50 in.(0.25 in.)
1.00 in.(0.50 in.)
2.00 in.(1.00 in.)
4.00 in.(2.00 in.)
CW
mm/m
0.42(0.21)
0.83(0.42)
1.66(0.83)
3.04(1.66)
Table I
Degrees
0.02(0.01)
0.05(0.02)
0.10(0.05)
0.17(0.09)
11