Controller X-25/X-45
2. Rotate the controller and secure it in the
installation position as shown in Illust. 3.
Illust. 3: Installation position
(1)
Opening for operation position
(2)
Opening for installation position
3. Loosen the screw with hexalobular socket
(see position (2) in Illust. 4) and put it to one
side.
4. Slide the connection panel cover (see po-
sition (1) in Illust. 4) upwards until it audibly
locks into place.
5. Fold down the supply line cover (see posi-
tion (3) in Illust. 4) and put it to one side.
138116080-V01.04.2020
1
2
Illust. 4: Opening of the controller
(1)
Connection panel cover
(2)
Screw with hexalobular socket
(3)
Supply line cover
6. Sever the cable ties securing the electrical
supply lines in place for tension relief with
a side cutter.
If required, mark the lines according
to your needs to facilitate cabling of
the new controller.
7. Loosen the clamping connections.
Loosen the clamping connections by
carefully holding down the orange
spring mechanism with a fine slot
screwdriver while pulling out the
lines.
8. In case of a fresh water station Regumaq
X-45, also loosen the plug-in connections
(flow sensor (Sika) and touch operating
element (display)).
9. Remove the controller.