The follower must be in the correct position!
Otherwise the switching mechanism will be damaged.
The follower only needs to be adjusted with a mortise lock with emer-
gency opening log.
Adjust follower of single profile cylinder as shown
in the illustration on the right. The follower should
always point in the direction of the door hinge.
The position of the single profile cylinder should be checked care-
fully before screwing in the forend screw (page 47, fig. 12).
The forend screw supplied with the single profile cylinder must be
used with emergency opening log. The length of the forend screw
should not exceed the backset + max. 10 mm, otherwise the emer-
gency opening log sensor may be destroyed..
1.
Slide single profile cylinder into door lock until forend
screw can be screwed in from the edge of the door.
Check whether the follower (locking lug) rotates
smoothly when the key is turned. Otherwise correct the
position of the single profile cylinder.
2.
Tighten single profile cylinder with forend screw.
Re-check whether the follower (locking lug) rotates
smoothly when the key is turned. Otherwise correct the
position of the single profile cylinder.
The single profile cylinder is only used for emergency opening, not for
locking.
Attempting to lock the door using force may damage the mortise lock!
Dialock Door Terminals DTSH, DTSH FH - Status: 07.2008 - 732.29.134