General Information; Mounting/Installation; Hoesch Combi-Plus" (Additional Equipment); Hoesch Backsiphonage Preventer For Concealed In-Wall Installation (Accessories) - HOESCH Deluxe Instructions De Montage Et D'utilisation

Table des Matières

Publicité

01

General information

All whirltubs produced by HOESCH are delivered on a self-
supporting frame with adjusted height. The system compo-
nents (whirl pump, control unit and blower) are located in
places shown in the annexed dimensioned diagram. In case
of models where you can choose between the factory-made
right-hand and left-hand version, the right-hand version is
delivered as a standard (always looking from the outside,
standing in front of the drain/ overfl ow fi tting).
What you should pay attention to:
■ Check whether the delivery is complete and undamaged.
■ We will not be liable for damages that occur during
transport and storage.
■ Do not raise the bathtub with previously installed pipe
system! Avoid any impacts!
■ During the installation cover the bathtub surface and
any system elements that stick out, which will protect
them against damages and excessive dirt.
■ Individual elements of the system must remain acces-
sible for later maintenance works!
People with various diseases such as serious infections,
blood clots, kidney failure, heart disease, diabetes should
use the whirl system after consultation with a doctor, which
allows for the use of appropriate therapy. We also recom-
mend medical consultation for pregnant women. The whirl
massage is exhaustive for children, they should not be left
unattended in such a bath. The existing system is not intend-
ed for use by persons (also children) with reduced physi-
cal, sensory or mental capabilities, or people which do not

02.02 Hoesch backsiphonage preventer for concealed in-wall installation (accessories)

Mains
Connections to be made at the installation site (min. R 1/2" necessary):
Connection C (top):
Connection to backsiphonage preventer, outlet side.
Connection B (middle): Connection to backsiphonage preventer, inlet side.
Connection A (bottom): Cold water supply via accessible shut-off valve, 3-5 bar supply pressure necessary.
Install cold water connection for system-fl ushing via accessible shut-off valve (e.g. in-wall valve) and a
dirt fi lter on site. Flush the piping suffi ciently before connection in accordance with DIN 1988!
have any experience or are not familiar with the equipment
unless it is done under adult supervision or in accordance
with usage instruction guidelines. One must pay attention
to children who should not have any access to the device.
Older people that move slowly or disabled persons should
use the bath carefully.
02

Mounting/Installation

Place the bathtub and level it with
the help of plastic legs with adjusted
height. Protect the leg with a fl at se-
curing nut. For acoustic insulation (in
order to avoid the transfer of material
sound to the wall), use a wall profi le
available in the market (article No.
6915, essential equipment). In case
of models that are intended to bo con-
nected with the wall, an edge strap for
the bathtub is essential (essential equipment: bathtub an-
chor, article No. 690401, install according to the attached
installation manual). During the installation please pay at-
tention to the fact that the apron must support the bathtub
edge!
02.01 „HOESCH Combi-Plus" (additional
equipment)
(bathtub tap with special drain / overfl ow fi tting)
An additional pipe interrupter is essential for the installa-
tion. Water connection should be made according to the at-
tached installation manual.
Mains
GB
17

Publicité

Table des Matières
loading

Table des Matières