Télécharger Imprimer la page
Napoleon Rosedale Serie Manuel D'installation
Masquer les pouces Voir aussi pour Rosedale Serie:
Les langues disponibles

Les langues disponibles

Liens rapides

NATURAL GAS MODELS:
PROPANE GAS MODELS:
SAFETY INFORMATION
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage
.
- Do not store or use gasoline or other
fl ammable vapours and liquids in the vicinity
of this or any other appliance.
-WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from
a neighbour's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fi re department.
- Installation and service must be
performed by a qualifi ed installer,
service agency, or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certifi ed kit is used.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
$10.00
ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)
RD2NE
RD2PE
INSTALLATION MANUAL
Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com
ADD MANUAL TITLE
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
CSA 2.33 AND ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS
CSA /
IF SEPARATE MANUALS, ADD "PLACE BARCODE
INTERTEK
LOGO
Product Name / Code
Rosedale™ Series
(MUST use title from Price Book)
ADD ____ ILLUSTRATED
ADD PRODUCT IMAGE
FOR INDOOR USE ONLY
IF INSTALLATION + OPERATION, ADD SERIAL
NUMBER LABEL HERE
place barcode label on the
LABEL ON THE OWNER'S MANUAL"
W415-10009334 / --1 / 01.06.26
ENGLISH
FRENCH PG. 41
(RD2NE illustrated)
owner's manual
loading

Sommaire des Matières pour Napoleon Rosedale Serie

  • Page 1 LABEL ON THE OWNER’S MANUAL” LOGO Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone 1 (866) 820-8686 • www.napoleon.com • hearth@napoleon.com $10.00 W415-10009334 / --1 / 01.06.26...
  • Page 2 safety information WARNING DANGER • This appliance is hot when operated and can cause severe burns if contacted. • Any changes or alterations to this appliance or its controls can be dangerous and is prohibited. HOT GLASS WILL CAUSE • Do not operate appliance before reading and BURNS.
  • Page 3 • Do not allow wind or fans to blow directly into the appliance. Avoid any drafts that alter burner fl ame RAAK HET GLAS NIET AAN TOT patterns. HET IS AFGEKOELD. DUTCH safety information LAAT KINDEREN NOOIT HET GLAS AANRAKEN. WARNING Dit apparaat is voorzien van een barrière die is ontworpen om het risico van brandwonden door het hete kijkglas te beperken.
  • Page 4 table of contents general information rates and efficiencies installation checklist rating plate information shut-off valve dimensions minimum clearance to combustibles installation planning levelling the appliance optional non-combustible installation chimney connection gas installation finishing minimum combustible mantel clearances safety barrier & door removal / installation log placement 3.3.1 OLKRD2 3.3.2 BLKRD2...
  • Page 5 1.0 general information general information When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft (305m).
  • Page 6 general information installation checklist GAS FIREPLACE INSTALLATION CHECKLIST Customer: Date Installed: Address: Installer: Model: Dealer: Serial #: Dealer Phone #: This checklist is a reference tool only. It is not intended as a subs�tute for the installa�on instruc�ons. Fireplace Installa�on IF NOT, PLEASE EXPLAIN WHY? Is the fireplace level and secured? Are the factory supplied non-combus�ble materials installed?
  • Page 7 general information WARNING • Always light the pilot whether for the first time or if the gas supply has run out, with the glass door opened or removed. • Provide adequate clearance for servicing and operating the appliance. • Provide adequate ventilation. •...
  • Page 8 Recessed depth X” Profondeur d’encastré une face X” L’appareil doit être ventilé à l’aide de l’ensemble d’évacuation propre à Napoleon. Référez au *** Mantel X” from appliance opening *** Tablette X” de l’ouverture de l’appareil manuel d’installation pour les spécifications d’évacuation. Il est nécessaire de bien réinstaller et *** Maximum horizontal extension: *** L’extension horizontale maximale: X”.
  • Page 9 general information dimensions Back View Top View 17 1/16" 434mm 4 1/2" 114mm 1 13/16" 6 3/4" 27 7/16" 45mm 171mm 697mm 2 15/16" 75mm 10 1/2" 17 3/4" 17 5/16" 266mm 451mm 440mm 1 5/8" 41mm 5" 126mm 22 9/16" 573mm 15 7/16"...
  • Page 10 2.0 installation planning installation planning WARNING • Risk of fi re! Maintain specifi ed air space clearances to vent pipe and appliance. Clean out ashes from the inside of the wood-burning appliance. Make sure that the chimney and wood-burning appliance are in a clean and sound condition and constructed of non-combustible materials. If necessary have any repair work done by a qualifi ed person before installing the insert.
  • Page 11 installation planning optional non-combustible installation Brick facing may be removed and replaced with non-combustible materials such as steel studs and concrete board. The opening between the firebox and non-combustibe materials must be sealed so as the heat cannot run between the face of the wood fireplace and the re-facing materials. Insert must be pulled out so the appliance is flush with the finishing materials and the safety barrier protrudes from the finished non-combustible enclosure (existing wood burning appliance).
  • Page 12 installation planning chimney connection Chimney installation must conform to both national and local code requirements. The chimney must be lined with one 3" (76mm) diameter liner for intake and one 3" (76mm) diameter liner for exhaust. The minimum and maximum vent lengths are 10' (3m) and 45' (14m) respectively.
  • Page 13 installation planning We recommend the following method of sealing off the damper area around the liner: Measure the throat of the appliance and mark this shape on a piece of 24 gauge sheet metal (flue cover). Cut a 6 3/4" (171mm) hole to lie directly below the appliance flue opening. Allow 2" of material for a flange on all sides and cut to these measurements.
  • Page 14 3.0 finishing finishing WARNING • Risk of fi re! • Never obstruct the front opening of the appliance. • The front of the appliance must be fi nished with any non-combustible materials such as brick, marble, granite, etc., provided that these materials do not go below the specifi ed dimension, as illustrated. •...
  • Page 15 finishing safety barrier & door removal / installation WARNING • Glass may be hot. Do not touch glass until cooled. • If equipped with door latches that are part of a safety system, they must be properly engaged. Do not operate the appliance with latches disengaged.
  • Page 16 finishing log placement WARNING • Failure to position the logs in accordance with these diagrams or failure to use only logs specifi cally approved with this appliance may result in property damage or personal injury. • Logs must be placed in their exact location in the appliance. Do not modify the proper log positions, since appliance may not function properly and delayed ignition may occur.
  • Page 17 finishing logo placement INSERT Remove the backing of the logo supplied and place, as illustrated. 1/2"(12.7mm) LOGO IMAGE 1/2"(12.7mm) HERE 45.5 glowing embers WARNING • Completely blocking the burner ports can cause an incorrect flame pattern, carbon deposits and delayed ignition.
  • Page 18 finishing 4.0 electrical information WARNING • Do not wire 110 volts to the valve or wall switch. W415-10009334 / --1 / 01.06.26...
  • Page 19 5.0 operation operation WARNING • If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury, or loss of life. • If applicable, always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door opened or removed.
  • Page 20 In order to start your pilot, turning the main burner on with the remote and then turning it off will reactivate the continuous pilot mode and reset the seven day timer. For further information, refer to: www.napoleon.com/pilotondemand note: Installation/operating instructions for the remote control are provided in the remote control packaging.
  • Page 21 operation battery installation The appliance is equipped with a battery backup in case of a power outage. 4 "AA" batteries must be installed in the battery holder before the appliance can operate by battery backup. 1. Remove the safety barrier (see "safety barrier & door removal / installation" section). 2.
  • Page 22 upper 3/8" to 1/2" (12.7mm - 9.5mm) of 6.0 adjustments adjustments thermocouple & thermopile pilot burner adjustment Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow. PSE LONG SENSOR Check Pressure Readings: Inlet pressure can be checked by turning screw (A) counter- clockwise 2 or 3 turns and then placing pressure gauge tubing...
  • Page 23 adjustments air shutter adjustment note: Adjustment may be required depending on fuel type, vent configuration and altitude. Air adjustments should be made using the handle to get the desired flame. 1. Remove the safety barrier (see "safety barrier & door removal / installation" section). 2.
  • Page 24 7.0 maintenance maintenance WARNING • Turn off the gas and electrical power before servicing the appliance. • Appliance may be hot. Do not service until appliance has cooled. • Do not use abrasive cleaners on glass. • Do not paint the pilot assembly. This appliance and its venting system (if equipped) should be inspected before use and at least annually by a qualifi ed service person.
  • Page 25 • Using a vacuum with soft brush attachment, gently remove any dirt, debris, or carbon build up from the logs, fi rebox, and burner. For glass media, follow the installation instructions for pre-cleaning. • Gently remove any build-up on the pilot assembly including thermopile, thermocouple, fl ame sensor, and maintenance igniter (if equipped).
  • Page 26 maintenance care of plated parts If the appliance is equipped with plated parts, you must clean fi ngerprints or other marks from the plated surfaces before operating the appliance for the fi rst time. Use an ammonia-free or vinegar-based cleaner and a towel to clean.
  • Page 27 maintenance LED replacement 1. Remove safety barrier and glass door (see "safety barrier & door removal / installation" section). 2. Remove the logs and media. 3. Remove porcelain radiant panels (PRPs) or brick panels (if applicable). 4. Remove the media tray (see "media tray removal"). 5.
  • Page 28 maintenance valve train service access 1. Remove safety barrier and glass door (see "safety barrier & door removal / installation" section). 2. Remove the logs and media. 3. Remove porcelain radiant panels (PRPs) or brick panels (if applicable). 4. Remove media tray (see "media tray removal" section).
  • Page 29 8.0 replacement parts replacement parts WARNING • Failure to position the parts in accordance with this manual or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury. Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts can be ordered through your Authorized dealer / distributor.
  • Page 30 replacement parts overview W415-10009334 / --1 / 01.06.26...
  • Page 31 Ref. Part # Description Stocked W272-0005 Foot, Adjustable Level W385-2010 Logo, Napoleon W010-3554 Assembly, Door Latch W010-10008111 Assembly, Vent Slide W010-10004466 Assembly, Collar Weld W290-10004756 Gasket, Vent Connection W660-0126-SER Remote, PF2 W010-10004906-SER Assembly, Door Complete W010-10005340-SER Assembly, Standard Safety Barrier...
  • Page 32 replacement parts valve train assembly W415-10009334 / --1 / 01.06.26...
  • Page 33 replacement parts Ref. Part # Description Stocked W585-10008035 Shield, Pilot W010-4895 Pilot Assembly (NG) W010-4896 Pilot Assembly (LP) W290-10009350 Gasket, Pilot W080-10008154 Bracket, Pilot W290-10005166 Gasket, Pilot Housing W035-10004904 Base, Burner Tray W290-10004902 Gasket, Valve Train W325-10002272 Handle, Air Shutter W080-10002738 Bracket, Air Shutter Adjust W235-0046...
  • Page 34 replacement parts log sets Ref. Part # Description Stocked W135-10005444 Log #1 Rear (OLKRD2) W135-10005458 Log #1 Rear (BLKRD2) W135-10005445 Log #2 Left Middle (OLKRD2) W135-10005439 Log #2 Left Middle (BLKRD2) W135-10009620 Log #3 Right Middle (OLKRD2) W135-10009619 Log #3 Right Middle (BLKRD2) W135-10005446 Log #4 Left Crossover (OLKRD2) W135-10005440...
  • Page 35 troubleshooting SIT ELECTRONIC IGNITION troubleshooting 3/8” - 1/2” 3/8” - 1/2” WARNING (9.5mm - 12.7mm) (9.5mm - 12.7mm) Flame must envelop • Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door open or La flamme doit envelopper upper la sonde de flamme de...
  • Page 36 Check that venting is installed correctly. appliances). Room is in negative pressure; increase fresh air supply. troubleshooting symptom problem test solution Pilot will not light. Makes Wiring: short, loose, or damaged Verify the thermocouple/sensor is clean and the wiring is undamaged. Verify the interrupter block is not damaged or too tight.
  • Page 37 symptom problem test solution Wire connector pins are bent. Straighten pins. Valve wiring is damaged. Replace valve. troubleshooting Lights or blower Control module switch in Verify ON/OFF switch is in the “I” position which denotes on. won’t function (if wrong position. equipped).
  • Page 38 Napoleon neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. Napoleon will not be responsible for: over- fi ring, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting confi gurations, insuffi cient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
  • Page 39 notes W415-10009334 / --1 / 01.06.26...
  • Page 40 Phone protected by one or more U.S. and Canadian and/or foreign Wolf Steel Ltd. Canada patents or patents pending. 24 Napoleon Road, Barrie, 1-866-820-8686 Les produits de NAPOLEON® sont protégés par un ou Ontario, L4M 0G8, Canada plusieurs brevets américains,...
  • Page 41 LOGO LABEL ON THE OWNER’S MANUAL” manuel du propriétaire Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 1(866)820-8686 • www.napoleon.com • hearth@napoleon.com W415-10009334 / --1 / 01.06.26 $10.00...
  • Page 42 NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot consignés de sécurité viewing glass is provided with this appliance and must be installed for the protection of children and other at-risk AVERTISSEMENT individuals.
  • Page 43 continue de s’éteindre, faire réparer. Garder propres le brûleur et le compartiment de contrôle. • Cet appareil ne devra être modifi é en aucun cas. • Ne laissez pas les ventilateurs souffl er directement sur l’appareil. Empêchez les courants d’air de modifi er consignés de sécurité...
  • Page 44 table de matières information générales taux et efficacités vérification d’installation information à propos de la plaque d'homologation vanne d’arrêt dimensions dégagements minimaux aux matériaux combustibles planification de l'installation mise à niveau l'appareil installation non combustible optionnelle installation de la cheminée branchement du gaz finitions dégagements minimaux au manteau combustible...
  • Page 45 1.0 information générales information générales Lorsque l'appareil est installé à une altitude de plus de 4 500 pieds (1382m) et en l'absence de recommendations particulières de l'autorité compétente locale, l'indice certifié du débit à haute altitude devra être réduit au taux de 4% pour chaque 1 000 pi (305m) supplémentaire.
  • Page 46 information générales vérification d’installation LISTE DE VÉRIFICATION POUR L'INSTALLATION D'UN FOYER AU GAZ Client : Date d'installa�on : Adresse : Installateur : Modèle : Détaillant : N° de série : Téléphone : Ce�e liste de vérifica�on est fournie uniquement à �tre de référence. Elle n'est pas des�née à remplacer les instruc�ons d'installa�on.
  • Page 47 information générales AVERTISSEMENT • Allumez toujours la veilleuse, qu ce soit pour la première fois ou lorsque l'approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Prévoyez un accès suffisant pour entretenir et opérer l'appareil. • Assurez-vous d'une quantitée suffisante d'air de ventilation.
  • Page 48 Recessed depth X” Profondeur d’encastré une face X” L’appareil doit être ventilé à l’aide de l’ensemble d’évacuation propre à Napoleon. Référez au *** Mantel X” from appliance opening *** Tablette X” de l’ouverture de l’appareil manuel d’installation pour les spécifications d’évacuation. Il est nécessaire de bien réinstaller et *** Maximum horizontal extension: *** L’extension horizontale maximale: X”.
  • Page 49 information générales dimensions Vue arrière Vue de dessus 17 1/16" 434mm 4 1/2" 114mm 1 13/16" 6 3/4" 27 7/16" 45mm 171mm 697mm 2 15/16" 75mm 10 1/2" 17 3/4" 17 5/16" 266mm 451mm 440mm 1 5/8" 41mm 5" 126mm 22 9/16"...
  • Page 50 2.0 planification de l'installation planification de l'installation AVERTISSEMENT • Risque d’incendie! Conservez les dégagements nécessaires au conduit d’évent et à l’appareil. Retirez les cendres de l’appareil de chauffage au bois. Assurez-vous que la cheminée et l’appareil de chauffage au bois sont propres et en bon état et qu’ils sont construits avec des matériaux incombustibles. Si nécessaire, faites faire les travaux de réparation par une personne qualifi ée avant d’installer l’encastré.
  • Page 51 planification de l'installation installation non combustible optionnelle Le parement de brique peut être retiré et remplacé par des matériaux non combustibles tels que des montants d’acier et des panneaux de béton. L’ouverture entre la boîte à feu et les matériaux non combustibles doit être scellée afin d’empêcher la chaleur de circuler entre la façade du foyer au bois et les matériaux de re-revêtement.
  • Page 52 planification de l'installation installation de la cheminée L’installation de la cheminée doit être conforme aux normes des codes nationaux et locaux. La cheminée doit être munie d'un conduit de 2" (51mm) ou 3" (76mm) de diamètre pour la prise d'air et d'un conduit de 3" (76mm) de diamètre pour l'évacuation.
  • Page 53 planification de l'installation Nous recommandons la méthode suivante pour scller la section du registre autour de la gaine: Mesurez la gorge de l'appareil et dessinez sa forme sur un morceau de tôle de calibre 24 qui servira de plaque d'isolement; découpez une ouverture de 6 3/4" (171mm) de diamètre alignée directement avec l'ouverture du conduit d'évacuation de l'appareil.
  • Page 54 3.0 finitions finitions AVERTISSEMENT • Risque d’incendie! • N’obstruez jamais l’ouverture sur le devant de l’appareil. • La façade de l’appareil doit être faite de matériaux incombustibles comme de la brique, du marbre, du granite, etc., à condition que ces matériaux ne se trouvent pas en deçà de la dimension spécifi ée tel qu’illustré. Comme alternative, vous pouvez utiliser le panneau de gypse comme fi nition pour votre appareil, voir les illustrations à...
  • Page 55 finitions enlèvement et installation de la barrière de protection et la porte AVERTISSEMENT • La vitre peut être chaude. Ne touchez pas la vitre jusqu’à ce qu’elle ait refroidi. • Si équipé avec les loquets de porte qui font partie d’un dispositif de sécurité, ils doivent être adéquatement verrouillés.
  • Page 56 finitions disposition des bûches AVERTISSEMENT • Omettre de positionner les bûches conformément aux schémas ou omettre d’utiliser uniquement des bûches spécifi quement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles. • Les bûches doivent être placées correctement à l’intérieur de l’appareil. Ne changez pas la position des bûches car l’appareil risque de ne pas fonctionner adéquatement et un retard d’allumage risque de se produire.
  • Page 57 finitions mise en place du logo INSERT Retirez le papier dorsal du logo et placez-le sur comme illustrée. 1/2"(12.7mm) IMAGE LOGO HERE 1/2"(12.7mm) 45.5 braises incandescentes AVERTISSEMENT • Obstruez pas ni fermer les orifices du brûleur. Le blocage des orifices du brûleur peut créer une flamme irrégulière, des dépôts de carbone et un retard d’allumage.
  • Page 58 finitions 4.0 renseignements électriques AVERTISSEMENT • Ne raccordez pas 110 volts à la soupape ou à l’interrupteur mural. W415-10009334 / --1 / 01.06.26...
  • Page 59 5.0 fonctionnement fonctionnement AVERTISSEMENT • Si ces instructions ne sont pas suivies à la lettre, un incendie ou une explosion pourraient s’ensuivre, causant des dommages matériels, des blessures corporelles ou des pertes de vie. • Si applicable, allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée.
  • Page 60 Pour allumer votre veilleuse, allumer le brûleur principal avec la télécommande, puis l’éteindre, réactivera le mode de veilleuse continue et réinitialisera la minuterie de sept jours. Pour plus d’informations, consultez le site : www.napoleon.com/pilotondemand note: Les instructions d’installation et d’utilisation de la télécommande sont fournies dans l’emballage de la télécommande.
  • Page 61 fonctionnement installation des piles L’appareil est équipé d’une batterie de secours en cas de panne de courant. Quatre piles « AA » doivent être installées dans le support de piles pour que l’appareil puisse fonctionner sur la batterie de secours. 1.
  • Page 62 3/8" to 1/2" thermocouple et (12.7mm - 9.5mm) of thermopile thermocouple & de 3/8" à 1/2" 6.0 réglages réglages thermopile (9.5mm - 12.7mm) réglage de la veilleuse Ajustez la vis de la veilleuse pour obtenir une fl amme de taille normale. Tournez vers la droite pour réduire PSE LONG SENSOR l’apport de gaz.
  • Page 63 réglages réglage du venturi note: Un ajustement peut être nécessaire selon le type de combustible, la configuration de la ventilation et l'altitude. Les réglages de l'air doivent être effectués à l'aide de la manette afin d'obtenir la forme et la hauteur de flamme souhaitées 1.
  • Page 64 entretien 7.0 entretien AVERTISSEMENT • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. • L’appareil peut être chaud. Attendez qu’il soit refroidi avant d’en faire l’entretien. • N’utilisez pas de produits abrasifs. • Ne peinture pas l’assemblage de la veilleuse. Cet appareil et son système d’évacuation (le cas échéant) doivent être inspectés avant la première utilisation et au moins une fois par an par un technicien qualifi é.
  • Page 65 brique, etc.) • À l’aide d’un aspirateur muni d’une brosse souple, aspirez les saletés, les débris et les dépôts de carbone entretien sur les bûches, la chambre de combustion et le brûleur. Pour les braises de verre, suivez les instructions de prénettoyage.
  • Page 66 entretien soins des pièces plaquées Si l’appareil est muni de pièces plaquées, vous devez enlever toutes traces de doigts ou autres marques des surfaces plaquées avant d’allumer l’appareil pour la première fois. Utilisez les nettoyants sans ammoniaque ou à base de vinaigre. Si la surface plaquée n’est pas bien nettoyée avant le premier allumage de l’appareil, elle risque de rester marquée en permanence.
  • Page 67 entretien remplacement des DEL 1. Retirez la barrière de sécurité et la porte vitrée (voir la section « dépose / installation de la barrière de sécurité et de la porte »). 2. Retirez les bûches et les éléments décoratifs. 3. Retirez les panneaux radiants en porcelaine (PRP) ou les panneaux de briques (le cas échéant). 4.
  • Page 68 entretien accès au train de soupapes pour entretien 1. Retirer la barrière de sécurité et la porte vitrée (voir la section « Retrait / installation de la barrière de sécurité et de la porte »). 2. Retirer les bûches et les matériaux décoratifs.. 3.
  • Page 69 8.0 pièces de rechange pièces de rechange AVERTISSEMENT • Omettre de positionner les pièces conformément à ce manuel ou d’utiliser uniquement des pièces spécifi quement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles. Contactez votre détaillant pour les questions concernant les prix et la disponibilité des pièces de remplace- ment.
  • Page 70 pièces de rechange vue d’ensemble W415-10009334 / --1 / 01.06.26...
  • Page 71 Réf. Pièce no Description En stock W272-0005 Pied, niveau ajustable W385-2010 Logo, Napoleon W010-3554 Loquet de porte, assemblé W010-10008111 Ensemble, glissière d’évent W010-10004466 Assemblage, collerette soudée W290-10004756 Joint, connexion de ventilation W660-0126-SER Télécommande PF2 W010-10004906-SER Assemblage, porte complète W010-10005340-SER Assemblage, barrière de sécurité...
  • Page 72 pièces de rechange ensemble du train de soupapes W415-10009334 / --1 / 01.06.26...
  • Page 73 pièces de rechange Réf. Pièce no Description En stock W585-10008035 Écran, veilleuse W010-4895 Assemblage du veilleur (NG) W010-4896 Assemblage du veilleur (PL) W290-10009350 Joint, veilleur (SIT) W080-10008154 Support, veilleur W290-10005166 Joint, boîtier de la veilleuse W035-10004904 Base, plateau du brûleur W290-10004902 Joint, système de soupapes W325-10002272...
  • Page 74 pièces de rechange jeu de bûches Réf. Pièce no Description En stock W135-10005444 Bûche no 1 – Arrière (OLKRD3) W135-10005458 Bûche no – Arrière (BLKRD3) W135-10005445 Bûche no 2 – Centre gauche (OLKRD3) W135-10005439 Bûche no 2 – Centre gauche (BLKRD3) W135-10009620 Bûche no 3 –...
  • Page 75 3/8" to 1/2" 1/2" mm - 9.5mm) of (9.5mm - 12.7mm) hermocouple guide de dépannage guide de dépannage AVERTISSEMENT CTRONIC IGNITION 3/8” - 1/2” 3/8” - 1/2” (9.5mm - 12.7mm) (9.5mm - 12.7mm) • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée.
  • Page 76 guide de dépannage symptôme problème solution La veilleuse ne s’allume Câblage: pénurie, connexion Vérifi ez qu’il n’y a pas de connexions desserrées du thermocouple ni sonde de fl amme. pas. Il y a du bruit mais desserrée (rectifi cation de la Vérifi ez l’interrupteur de bloc n’est pas endommagée ou trop serré.
  • Page 77 s’allume. Les broches de connecteur de Redresser les fi ls. télécommmande sont faibles. est relié à la terre. Vérifi er la masse (court); réparer ou remplacer les fi ls. Le télécommande ne La télécommande s’allume mais Réinitiliser en tourant l’alimentation « off » puis « on ». fi ls sont courbeés.
  • Page 78 Pendant les 10 premières années, Napoleon réparera ou remplacera les pièces défectueuses couvertes par la garantie à vie à sa discrétion, sans frais. De 10 ans à vie, Napoleon fournira les pièces de rechange à 50 % du prix de détail actuel.
  • Page 80 50 ans de solutions pour le confort de votre maison. Les produits de NAPOLEON® Adresse Téléphone sont protégés par un ou plusieurs brevets américains, Wolf Steel Ltd. Canada canadiens et/ou étrangers au par des brevets en instance. 24 Napoleon Road, Barrie,...

Ce manuel est également adapté pour:

Rosedale rd2neRosedale rd2pe