Automatic power saving function

This unit has an automatic power saving function.
If the automatic power saving function is set to on, the unit will
automatically enter standby mode if there is no audio input for
about 30 minutes.
Turning automatic power saving on and off
1
While pressing the DIMMER/METER GAIN
button, set the STANDBY/ON switch to ON.
2
Immediately after setting the STANDBY/ON
switch to ON, release the DIMMER/METER GAIN
button.
Release immediately after setting
the STANDBY/ON switch to ON.
Releasing the DIMMER/METER GAIN button will switch the
automatic power saving function between on and off and the
level meters will blink.
You can check the automatic power saving setting by the blink-
ing of the level meters at this time.
Automatic power saving function on
Meters blink every 3 seconds.
Automatic power saving function off
After blinking twice at 0.4-second intervals, meters continue to
alternately become lit and unlit at 3-second intervals.

Restoring default settings

1
While pressing the DIMMER/METER GAIN
button, set the STANDBY/ON switch to ON.
2
When the level meters blink, release the
DIMMER/METER GAIN button.
The factory default settings will be restored, and after the level
meters blink twice at 0.4-second intervals, the unit will enter
standby.
Keep pressing until the level
meters blink.
EN