Whirlpool WET3300XQ Instructions Pour L'installation page 15

Masquer les pouces Voir aussi pour WET3300XQ:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.
Connect neutral ground wire
and neutral wire
Connect neutral ground wire (E) and place
hooked end (hook facing right) of neutral
wire (white or center wire) (C) of direct
wire cable under center screw of terminal
block (B). Squeeze hooked ends together
and tighten screw.
4.
Connect ground wire
Connect ground wire (green or bare) (F) of direct wire cable
to external ground conductor screw (A). Tighten screw.
5.
Connect remaining wires
Place hooked ends of remaining direct wire cable wires
under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to
"Venting Requirements."
3-Wire Direct Wire Connection
IMPORTANT: Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
1.
Prepare your 3-wire cable for
direct connection
B
E
C
Direct wire cable must have 5 ft. (1.52 m) of extra length so
washer/dryer may be moved if needed.
1
Strip 3
/
" (89 mm) of outer covering from end of cable. Strip
2
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape wire ends
into hooks.
2.
Remove center screw
F
A
Remove center terminal block screw (B).
B
15

Publicité

Table des Matières
loading

Table des Matières