Cardin SL Série Mode D'emploi page 17

Masquer les pouces Voir aussi pour SL Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Terminal board connection
1-2
Programmer power supply 230 Vac
3-4
Transformer power output 230 Vac
5
Programmer power supply earth wire
5
Motor earth wire
7
TB (NC contact) stop button input (The opening of this contact interrupts
the cycle until a new movement command is given).
8
Common for all inputs and outputs.
9
FTCS (NC contact) Safety and control devices in input (stop photoelec-
tric cells). The opening of this contact will block all movement, until the
obstruction has been removed, due to the safety device cutting in, the
gate will then continue moving until it reaches a travel limit (only in the
automatic mode).
CSP (NC contact) safety buffer input). Opening this contact will provoke
a travel direction inversion of 10 cm, a pause of 3 minutes, after which
the motor will continue moving in the original direction after a 10 second
preflashing period has elapsed.
10
FTCI (NC contact) safety and control devices in input (photocells invert
the travel direction when an obstruction is detected). Opening this
contact will provoke a travel direction inversion during closure due to
the cutting in of the safety device.
11
Common for all inputs and outputs.
12
30 Vdc output, powering controlled external loads
13
LP 30 Vdc output for warning lights.
25 W intermittent activation (50%), 12,5 W continuous activation.
14
Common for all inputs and outputs.
15
LS 30 Vdc 3W output for an indicator light.
16
Common for all inputs and outputs.
17
30 Vdc output, powering permanent external loads
18
Common for all inputs and outputs.
19
TA (NO contact) opening button input.
20
Common for all inputs and outputs.
21
TC (NO contact) closing button input.
22
TD (NO contact) dynamic button input.
23
Common for all inputs and outputs.
L
230Vac
N
TRF 230Vac
L1
CTRL
30Vdc
7
8
9
10
11
12
13
23
24
19
20
21
22
B1
via radio
CN1
Motor Faston connection
CSER Serial line connection (only for diagnostics)
D1
Six-segment LED display
S1
Selection dip-switch
E1
Encoder connection
F1
1.6A delayed fuse (230 Vac motor power protection)
F2
3.15A rapid fuse (24V transformer power protection)
F3
10A rapid fuse (motor power protection from the transformer)
F4
10A rapid fuse (battery powered operation motor protection)
(1)
.
(1)
.
L4
M1
OUT
30Vdc
14
15
16
17
18
25 26 27
J4
24
TAL (NO contact) limited opening button input.
25
EMRG 1 (NO contact) emergency manoeuvring button input 1
26
EMRG 2 (NO contact) emergency manoeuvring button input 2
27
Common for both emergency buttons.
28
Outer conductor for the radio receiver antenna
29
Inner conductor for the radio receiver antenna (if an external antenna
is fitted use a coaxial type cable RG58 with an impedance of 50Ω).
Note (
) The total of the 2 external device outputs must not exceed 10W.
1
ALL UNUSED NC CONTACTS MUST BE JUMPED.
Switch on the power and make sure that the indicator LEDS are in the following
condition (note: If the display is off you can press the PROG key to show the
status of the safety devices.
- L1 Power on
- L2 Wrong battery connection
- L3 Transmitter code programming indicator
- L4 Battery charging
- L5
- L6
- L7
- L8
- L9
- L10
- L11
Note (1)
on
and contact the after sales service.
Note (2)
on
Note (3) Check that the activation of the safety devices switches the correspond-
ing LEDS off.
If the green power on LED "L1" doesn't light up check the condition of the
fuses and the power cable connection at the transformer primary.
If one or more of the safety LEDS do not light up check the contacts of the
relative security devices and check that the unused safety device contacts
have been bridged.
R1
B1
J1
J2
F5 F3.15A
F4 F10A
J3
CN1
M
L2
F5
3.15A rapid fuse (24V battery powered operation protection)
J1
Radio channel selection
J2
Enable transmitter memorisation via radio
M1
Transmitter code memory module
P1
Transmitter code memorization button (MEMO)
P2
Transmitter code cancellation button (DEL)
P3
Programming button (PROG)
R1
Radio frequency module, 433 MHz for S449 transmitters
J3
Battery connection
J4
Transformer secondary protection
17
TB
FTCI
FTCS
CSP
TA
TC
TAL
TD/CH1
CS1206.01B DC0398
L5
L8
L10
L6
L7
L9
L11
P1
L3
E1
S1
ON
OFF
(1)
OFF
(2)
OFF
ON
(3)
(3)
ON
(3)
ON
OFF
OFF
OFF
OFF
D1
CSER
P2
P3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sl424ebss

Table des Matières