22 | English
Continuous Measurement (Tracking) (see figure E)
For continuous measurements, the measuring tool can be moved relative to the
target, whereby the measuring value is updated approx. every 0.5 seconds. In
this manner, as an example, you can move a certain distance away from a wall,
while the actual distance can always be read.
For continuous measurements, push button 6. The indicator for continuous
measurement (tracking) appears in the display
Press the measuring button 12 to initiate the measur-
ing procedure. Move the measuring tool until the re-
quired distance value is indicated at the bottom of the
display.
Pushing the measuring button 12 interrupts the con-
tinuous measurement. The current measured value is
indicated in the display. Repeated pushing of the measuring button 12 starts the
continuous measuring again.
Continuous measurement automatically switches off after 5 min. The last meas-
ured value remains indicated on the display. To cancel continuous measure-
ment, you can change the measuring function by pressing button 1, 3 or 5.
Deleting Measured Values
Briefly pressing button 7 deletes the last individual measuring value determined
in all measuring functions. Briefly pressing the button repeatedly deletes the in-
dividual measured values in reverse order.

Memory Functions

When switching off the measuring tool, the value in the memory is retained.
Storing/Adding Measured Values
Push the memory add button 2 in order to store the
current measured value – a length, area or volume
value, depending on the current measuring function.
As soon as a value has been stored, "M" is indicated
in the display and the "+" behind it briefly flashes.
If a value is already stored in the memory, the new value is added to the memory
contents, however, only when the measures of unit correspond.
As an example, when an area value is in the memory and the current measured
value is a volume value, the addition cannot take place. "Error" briefly flashes in
the display.
Subtracting Measured Values
Push the memory subtraction button 8 in order to subtract the current measured
value from the memory value. As soon as a value has been subtracted, "M" is in-
dicated in the display and the "–" behind it briefly flashes.
If a value is already stored in the memory, the new measured value can be sub-
tracted only when the measures of unit correspond (see "Storing/Adding Meas-
ured Values").
Displaying the Stored Value
Push the memory retrieve button 4 in order to display
the value stored in the memory. "M=" is indicated in
the display. When the memory contents "M=" is indi-
cated in the display, it can be doubled by pushing the
memory add button 2 or set to zero by pushing the
memory subtract button 8.