The alarm will automatically reactivate once the value has
fallen below the set temperature value or if a new value is
entered.
The outdoor weather alarm
When a set outdoor alarm has been triggered, it will flash on the
LCD display. The general outdoor alarm icon and HI / LO alarm
icon will flash accordingly. Example: In outdoor temperature
mode, the dew point icon will flash along the outdoor alarm and
the HI alarm icons when the dew point HI alarm is triggered.
This will indicate that the current alarm source is from the dew
point.
d. MIN / MAX Mode
Press MIN / MAX to enter the MAX mode. MAX and the
maximum record will be displayed.
Press MIN / MAX to enter the MIN mode. MIN and the minimum
record will be displayed.
Press MIN / MAX to return to the normal display mode.
In MAX mode, press + to display the following maximum values with their time and date: Indoor
humidity maximum – Indoor temperature maximum – Outdoor humidity maximum – Outdoor
temperature maximum – Pressure maximum.
In MIN mode, press + to display the following minimum values with their time and date: Indoor humidity
minimum – Indoor temperature minimum – Outdoor humidity minimum – Outdoor temperature minimum
– Pressure minimum.
Press SNOOZE / LIGHT to return to the normal display mode
Reset
The SET button resets the values in MIN or MAX mode. To reset the values:
In MIN or MAX mode, press and hold SET for 2 seconds to reset the MIN or MAX values and h-the time
and date.
To reset the device, remove the batteries from the device.
e. Calibrating Indoor and Outdoor Humidity
The WS1170 weather station allows you to calibrate both the indoor and the outdoor humidity. Humidity is
a difficult parameter to measure accurately. The calibration option allows you to zero out this error. Note
that you will need a hygrometer calibration pack (not included).
Proceed as follows:
1. Press SET and select the indoor humidity function.
2. Press + or MIN / MAX to increase or decrease the humidity setting in increments of 1 % until the setting
matches the calibrated humidity source.
3. Press and hold SET for 3 seconds to confirm.
4. Do the same for the outdoor humidity function.
Note: The remote outdoor sensor will not display the calibrated humidity level but only the measured
humidity level. The dew point calculation is based on the calibrated humidity level.
9. Troubleshooting
Problem
Transmission problem
Data on LCD is illegible  No data reception
Incorrect data
10.

Technical specifications

Temperature Range
Relative Humidity
Indoor Station
Atmospheric Pressure
Alarm Duration
21.01.2015
Possible Cause
 Distance between the two units is too long
 Shielding materials between two units
(thick wall, steel...)
 Interference from other sources
 Low batteries
 Low batteries
 Incorrect settings
Resolution 0.1°C
Resolution 1%
Resolution / Accuracy 0.1 hPa / 1.5 hPa
WS1170
Solution
 Reduce distance
 Find a different mounting location
 Eliminate interference sources
 Find a different mounting location
 Replace batteries
 Replace batteries
 Reprogram the weather station
0°C ~ +60°C (OFL displayed when out of range)
1% ~ 99%
919 hPa ~ 1080 hPa
120 sec
6
Temperature display mode
Dew point HI alarm triggered
Rev. 04
©Velleman nv