Operation
NOTICE! Danger of damaging the device!
A
To avoid drops in voltage and therefore performance, keep the ca-
ble as short as possible and only disconnect it when necessary.
For this reason avoid additional switches, plugs or power strips.
➤ Determine the required cross section of the cable in relation to
the cable length according to fig. 6, page 5.
Key for fig. 6, page 5
Co-ordinate axis
NOTICE! Danger of damaging the device!
A
Make sure that the polarity is correct.
➤ Before starting up the device for the first time, check whether
the operating voltage and the battery voltage correspond (see
type plate).
➤ Make sure that the cable at the positive battery terminal
(fig. 7 2, page 5) is protected with a 15 A fuse (fig. 7 3,
page 5).
➤ Plug the 12/24-V connection cable (fig. 1 2, page 3) into the
DC socket on the cooler (fig. 7 1, page 5).
➤ Connect the red cable (fig. 7 rt, page 5) to the positive terminal
of the battery (fig. 7 2, page 5).
➤ Connect the black cable (fig. 7 sw, page 5) to the negative
terminal of the battery (fig. 7 2, page 5).