ASSEMBLY
SQUARING THE BLADE TO THE MITER TABLE
See Figures 20 - 22
To square the blade at 0°:
Remove the battery pack from the tool.
Pull the saw arm all the way down and engage the lock
pin to hold the saw arm in transport position.
Lift the miter lock lever, then depress and hold the detent
release button to release the miter table.
Rotate the miter table until the scale indicator is posi-
tioned at 0°.
Release the detent release button and allow the miter
table to engage the 0° detent position. Push the miter
lock lever down to secure the miter table.
Push the bevel stop pin inward. See figure 12.
Loosen bevel lock knob and tilt saw arm until it is seated
in the positive 0° bevel stop (blade set 90° to miter table).
Tighten bevel lock knob.
Place a combination square against the miter table and
the flat part of saw blade.
NOTE: Make sure that the square contacts the flat part
of the saw blade, not the blade teeth.
Rotate the blade by hand and check the blade-to-table
alignment at several points.
The edge of the square and the saw blade should be
parallel as shown in figure 20.
If the top or bottom of the saw blade angles away from
the square as shown in figures 21 and 22, adjustments
are needed.
Loosen the bevel lock knob.
Adjust 0° bevel stop screw to bring saw blade into align-
ment with the square. See 0° Bevel Adjustment in the
Adjustments section.
BLADE
FIXED
MITER
FENCE
COMBINATION
SQUARE
CORRECT VIEW OF BLADE
SQUARE WITH MITER TABLE
MITER
MITER LOCK
TABLE
LEVER
Retighten bevel lock knob. Recheck blade-to-table
alignment.
To square the blade at 45°:
Loosen the bevel lock knob and set the saw arm at 45°
bevel. Tighten bevel lock knob.
NOTE: To obtain right bevel angles, pull the bevel stop
pin out and tilt the saw to the desired angle.
Using a combination square, check the blade-to-table
alignment as described earlier.
If adjustments are needed, refer to 45° Bevel Adjustment
in the Adjustments section.
Your saw has several scale indicators. After squaring adjust-
ments have been made, it may be necessary to loosen the
indicator screws and reset them to zero. See Figures 13-14.
FIXED
MITER
FENCE
VIEW OF BLADE NOT SQUARE WITH MITER TABLE,
FIXED
MITER
FENCE
VIEW OF BLADE NOT SQUARE WITH MITER TABLE,
Fig. 20
18 - English
COMBINATION
SQUARE
ADJUSTMENTS ARE REQUIRED
COMBINATION
SQUARE
ADJUSTMENTS ARE REQUIRED
Fig. 21