INSTALLATION MANUAL
TERENA - TERENA16
Web Based Access Control
SD CARD CONNECTOR
A
1 Giga octet SD Card, which must be inserted.
B
DIPSWITCH CORRESPONDENCE
dipswitch 1:
- ON = event with user name*,
- OFF = event without user name**.
dipswitch 2:
- OFF = the "OFF" position allows normal
functioning of the TERENA system.
- ON = if the dipswitch 2 is in the "ON" position,
the "LOW BAT" LED flashes, indicating
that a secure shut-down procedure is in progress.
Wait until the "RX", "TX", "AL" and "SCR" LEDs
are no longer lit up before disconnecting the TERENA.
After the TERENA has been shut down
with the dipswitch 2:
- Set the dipswitch back to the "OFF" position,
- Disconnect the battery and the mains supply,
- Then reconnect to the mains and battery
(the battery alone cannot power up the TERENA).
dipswitch 3:
- Reserved.
dipswitch 4:
- ON = Site reset, authorized on the administration page,
- OFF = Normal mode.
* dipswitch 1 : ON
When an event is displayed and printed, the user
name of the person who presented his/her tag
appears.
** dipswitch 1 : OFF
When an event is displayed and printed, the user
name of the person who presented his/her tag
does not appear, the tag is simply recognized.
Check system compliance with the CNiL
(independent administrative authority protecting privacy
and personal data in France exclusively)
C
USB HOST CONNECTOR
Reserved (CMPP)
D
USB DEVICE CONNECTOR
Reserved
cdvi.com
8
cdvigroup.com
.
E
RS232 CONNECTOR
Reserved
F
ETHERNET CONNECTOR
- Direct PC connection in local mode (crossover cable)
or using a HUB or Switch (straight-through cable).
- Connection to a local network (straight-through
cable) to the network distribution rack .
- Connected to the Ethernet network (RJ45 cable)
to the Ethernet router (BOX).
G
TERMINAL CORRESPONDENCE
3 point terminal block
BAT+
+ Battery 12 V - 7A
G1
BAT-
- Battery 12 V - 7A
3 point terminal block
AC
Power supply AC - 12 V (transformer)
G2
AC
Power supply AC - 12 V (transformer)
Ground (Yellow/Green)
17 point terminal block
1
Contact arming board 1 (Alarms)
2
Common
3
Contact arming board 2 (Alarms)
4
Contact arming board 3 (Alarms)
5
Common
6
Contact arming board 4 (Alarms)
A
A - RS485 Bus
GND
Cable shielding
G3
B
B- RS485 Bus
NO
Alarm contact (readers) normally open
C1
Common
NC
Alarm contact (readers) normally closed
NO
Alarm contact (alarm board) normally open
C2
Common
NC
Alarm contact (alarm board) normally closed
S1
Tamper contact
S2
Tamper contact
EN