INSTALLATION MANUAL
TERENA - TERENA16
Web Based Access Control
Signal control board (C1410S)
Board indicating the status of a reader zone, used
for entry/exit counting.
The board is connected to the central control unit
using a 2 wire cable (RS485 BUS >: Recommended
cables : 1 twisted pair, SYT1 8/10th shielded wire
(EIA-485 standard).
8 "Relay contact" outputs (Full zone*).
6 "Relay contact" outputs (Empty zone**).
The warning light on the board is not lit up
in the absence of a command. It is lit up and static
as soon as a command is sent.
The relay contacts on the board are NO contacts
(Normally Open) :
- Contact open when at rest = normal mode,
- Contact closed = warning light on board is lit up
and static, indicating zone status.
* Full zone : it is possible to indicate that the spaces
allocated to a zone are full (for example : parking
spaces with traffic lights).
** Empty zone : it is possible to indicate that the zone
is vacant and to authorize an action (for example : signal
a surveillance alarm on the premises).
C1410S board address settings:
Enrolment Reader for tags, cards and remote transmitters (Ref: CMPP)
TERENA
Connecting
MR (RF) or
MPM (Mifare
)
®
modules
CMPP
cdvi.com
12
cdvigroup.com
TERMINAL
CORRESPONDENCE
C
Common outputs
1
Contact NO Zone 1
2
Contact NO Zone 2
3
Contact NO Zone 3
4
Contact NO Zone 4
5
Contact NO Zone 5
6
Contact NO Zone 6
7
Contact NO Zone 7
8
Contact NO Zone 8
9
Contact NO Zone 1
10
Contact NO Zone 2
11
Contact NO Zone 3
12
Contact NO Zone 4
13
Contact NO Zone 5
14
Contact NO Zone 6
M
RS485 Cable shielding
A
"A" of the RS485 BUS
B
"B" of the RS485 BUS
V
12 V DC Power Supply
V
12 V DC Power Supply
relays 1 to 8:
- contact is open when at rest,
- contact is closed indicating that the zone is full.
relays 9 to 14:
- contact is open indicating that the zone is occupied,
- contact is closed indicating that the zone is vacant.
the enrolment reader is connected to the central
control unit using the uSB plug on the central
unit (see diagram).
- By default, the CMPP reader is in "Proximity"
technology mode. For "RF" and "Mifare®" technologies
you need to connect the MR (RF) module or the
MPM (Mifare
) module to your CMPP.
®
- Present the tag on the enrolment module,
- The code is displayed on the CMPP screen,
- To learn more about the enrolment and identification
stages and how to transfer the tag code to the central
unit, refer to the on-line help (Menu "Record").
EN
STATUS
Full
Full
Full
Full
Full
Full
Full
Full
Vacant
Vacant
Vacant
Vacant
Vacant
Vacant