- The relay contacts on the elevator board are NO
contacts (Normally Open). The contact is open
when in the rest position, and closed for the relay
command.
- The relay contacts are used for access authorization
to the elevator cabin buttons after presentation
of a tag in front of the reader installed in the cabin
(they do not allow elevator access requests
on floors).
The alarm board Inputs/Outputs : C14A/E and C14A/S
the alarm boards are divided into two categories,
reader boards (C14a/e) and report boards
(C14a/S). each C14a/e board has a corres-
ponding C14a/S board. the C14/e board has
dry contact inputs which read the information
supplied by the alarm and the C14a/S board
has outputs consisting of relays allowing it to
report alarm information.
- The board is connected to the central control unit
using a 2 wire cable (RS485 BUS >: Recommended
cables : - 1 twisted pair, SYT1 8/10th shielded wire
(EIA-485 standard).
- 14 command relays (access authorization to floor
buttons).
- C14D/A address settings are done using
dipswitches (max. 4 per central unit).
- They are armed (green button) in the "SITE"
configuration. The alarm may be armed either on
contact opening or closing (choice is possible).
C14a/e
The warning light on the board is flashing, indicating
that the board is functioning. The reader board
inputs are dry contacts. Caution : the opening
or closing time of the alarm detection contact must
not be less than 1 second for it to be taken into account.
C14a/S
The warning light on the board is not lit up in the
absence of an alarm. It is lit up and static as soon
as an alarm is detected. The relay contacts on the
report board are NO contacts (Normally Open):
- Contact is open when at rest = no alarm
in progress,
- Contact closed = alarm in progress and warning
light on the board is lit up and static.
Lift buttons
TERMINAL
C14A/E
C
Common contact relay
1
Input contact 1
2
Input contact 2
3
Input contact 3
4
Input contact 4
5
Input contact 5
6
Input contact 6
7
Input contact 7
8
Input contact 8
9
Input contact 9
10
Input contact 10
11
Input contact 11
12
Input contact 12
13
Input contact 13
14
Input contact 14
M
RS485 Cable shielding
A
"A" of the RS485
B
"B" of the RS485
V
12 V DC Power supply
V
12 V DC Power supply
C14d/a board address settings
(max. 4 per central unit):
Card 1
Card 2
EN
C14D/A
BUS RS485
C14A/S
Common contact relay
NO Contact Output 1
NO Contact Output 2
NO Contact Output 3
NO Contact Output 4
NO Contact Output 5
NO Contact Output 6
NO Contact Output 7
NO Contact Output 8
NO Contact Output 9
NO Contact Output 10
NO Contact Output 11
NO Contact Output 12
NO Contact Output 13
NO Contact Output 14
RS485 Cable shielding
BUS "A" of the RS485 BUS
BUS "B" of the RS485 BUS
12 V DC Power supply
12 V DC Power supply
Card 3
Card 4
cdvi.com