IMPORTANT:
Observe allgoverning codes a ndordinances.
[] It istheinstaller's responsibility
tocomply w ithinstallation
clearances
specified onthemodel/serial
rating plate. The
model/serial
rating plate islocated i nside t herange h ood on
therear w all.
[] Range h ood location should beaway f rom strong draft a reas,
such aswindows, doors and strong heating vents.
[] Cabinet opening dimensions
thatareshown m ust b eused.
Given d imensions
provide m inimum c learance. Consult your
cooktop/range
manufacturer
installation instructions
before
making a nycutouts.
[] Grounded electrical outlet isrequired. See"Electrical
Requirements"
section.
[] The hood isfactory s etforvented i nstallations.
For
recirculating
installations,
Recirculation
KitPart N umber
4396565, including vent c over and2charcoal filters are
available from your d ealer.
[] Allopenings inceiling a nd wall w here r ange h ood will b e
installed must b esealed.
Product
dimensions
5Y8"(14.9 crn) dia. -__.
exhaust collar
Interchangeable
FrontTrim
915/16"
(25.2 crn)
29_5A6 '' (76.0 crn) -30"
(76.2 crn) model
(51.3 cm)--.__35_5/_¢"
(91.3 cm) - 36" (91.4 crn) model
Vent and electrical
openings
and mounting
screw locations
centerline of
9 _/s,,
57/8"
exhaust collar
(14.9 crn)
(232 crn)
lt/4 '
13/_6,,
(3.2 crn)
(3.0 crn)
0
(10.0 crn)
electrical
knockouts
(19.0 crn)
centerline
of hood
installation
clearances
(76.2 crn) or
36" (91.4 crn) rnin.
opening width
\\
24" (61 crn) rnin.
30" (76.2 crn)
suggested
max.
bottom of hood to
cooking surface
70%¢
(178.8 crn)
rnin.
18" (45.7 crn)
76%¢
rnin. clearance
(193.8 crn)
upper cabinet
max.
to countertop
to bottom of
cabinet frame
36" (91.4 crn)
countertop
height
[]
Use a straight run or as few elbows as possible.
[]
Do not terminate the vent system in an attic or other enclosed
area.
[]
Do not use a 4" (10.2 cm) laundry-type wall caps.
[]
Vent system must terminate to the outside.
[]
Use only a 6" (15.2 cm) round metal vent. Rigid metal vent is
recommended.
Do not use plastic or metal foil vent.
[]
The size of the vent should be uniform.
[]
The vent system must have a damper. If roof or wall cap has a
damper, do not use damper supplied with the range hood.
[]
Use duct tape to seal all joints in the vent system.
[]
Use caulking to seal exterior wall or roof opening around the
cap.
[]
Determine which venting method is best for your application.