Settings Menu - Bosch D-tect 150 Professional Notice Originale

Masquer les pouces Voir aussi pour D-tect 150 Professional:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OBJ_DOKU-51842-001.fm Page 18 Friday, March 4, 2016 1:31 PM
18 | English
Changing the Operating Modes
Changing between different operating modes is possible with
selection buttons 10 and 12.
– Briefly press selection button 10 to select the next operat-
ing mode.
– Briefly press selection button 12 to select the previous op-
erating mode.
By selecting the operating modes, you can adapt the measur-
ing tool to different wall materials and suppress insignificant
objects (e.g. hollow spaces in brickwork). The current setting
is always shown in the operating-mode indication h of the dis-
play.
Universal Mode (default setting)
"Universal mode" is suitable for most applications in brick-
work or concrete. Plastic and metal objects as well as electri-
cal wiring are displayed. Hollow spaces in brickwork or empty
plastic pipes with a diameter of less than 2 cm are possibly
not displayed. The maximum measuring depth is 6 cm.
Concrete Deep
"Concrete deep" mode is particularly suitable for concrete
applications. Reinforcing steel, plastic and metal pipes, as
well as electrical wiring are displayed. The maximum measur-
ing depth is 15 cm.
Panel Heating
The operating mode "Panel heating" is particularly suitable
for detecting metal, metal-composite and water-filled plastic
pipes, as well as for electrical wiring. Empty plastic pipes are
not displayed. The maximum measuring depth is 8 cm.
Drywall
The operating mode "Drywall" is suitable for finding wooden
beams, metal framing and electrical wiring in drywalls (wood,
gypsum board, etc.). Filled plastic pipes and wooden beams
are displayed identically. Empty plastic pipes are not detect-
ed. The maximum measuring depth is 6 cm.
Hollow Block
The operating mode "Hollow block" is suitable for walls with
many air pockets. Metal objects and "live" conductors are de-
tected. Plastic tubes and voltage-free conductors are not de-
tected. The maximum detection depth is 6 cm.
Changing the Display Modes
Note: Changing the display modes is possible in any operat-
ing mode.
1 609 92A 26X | (4.3.16)
To switch from the standard start display to rule mode, press
and hold selection button 10 or 12.
?
N
8.8 cm
S
20.1 cm
18
19
20
21
cm
10 cm
20 cm
Prev.
Concrete deep
In the example, rule mode shows the same situation as in
figure D: Three steel bars equally apart. In rule mode, the
clearance between the detected object centres can be deter-
mined.
The measuring distance covered from the starting point (in
the example 20.1 cm) is displayed under the indication of the
allowable drilling depth l.
The three objects are displayed as rectangles in the small rule
above the operating-mode indication h.
Note: Both the indication of the allowable drilling depth l as
well as the material property m refer to the object pictured
black in the sensor.
To return to the standard start display, briefly press selection
button 10 or 12.
Note: Only the display is reset, not the measuring mode!
"Settings" Menu
To access the "Settings" menu, press the setup button 14.
To exit the menu, press the start button 11. The current set-
tings are saved. The standard start display for the measuring
process is activated.
Navigating in the Menu
Press the setup button 14 to scroll down.
Press the selection buttons 10 and 12 to select the values:
– Selection button 10 will select the right-hand or next value.
– Selection button 12 will select the left-hand or previous
value.
Language
In the "Language" menu, you can change the language of the
menu navigation. The default setting is "English".
Cut-off Time
In the "Cut-off time" menu, you can set certain time intervals
after which the measuring tool shall automatically shut off
when no measurements are taken or settings are carried out.
The default setting is "5 min".
Light Duration
In the "Light duration" menu, you can set a time interval with-
in which the display 16 shall be illuminated. The default set-
ting is "30 s".
22
23
30 cm
40
Next
Bosch Power Tools

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

3 601 k10 005