Technical Data; Inserting/Replacing The Batteries - Bosch D-tect 150 Professional Notice Originale

Masquer les pouces Voir aussi pour D-tect 150 Professional:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OBJ_DOKU-51842-001.fm Page 15 Friday, March 4, 2016 1:31 PM
g Outer edges, to be marked left and right via
marking aid 3
h Operating-mode indication
i Grey: Found object outside of the sensor range
j Black: Found object within the sensor range
k Centre line, corresponds with the marking aid 1
l Indication of the allowable drilling depth
m Indication of the object material
n "Live" wire indicator

Technical Data

Universal Detector
Article number
Measuring accuracy to the object
1)
centre a
Accuracy of the indicated allowable
1)
drilling depth b
Minimum distance between two neigh-
1)
bouring objects c
Operating temperature
Storage temperature
Batteries
Rechargeable batteries
Operating time, approx.
– Batteries (alkali-manganese)
– Rechargeable
batteries (2500 mAh)
Degree of protection
Dimensions
Weight according to EPTA-Procedure
01:2014
1) See graphic
c
b
a
2) Depending on size and type of object as well as material
and condition of the base material
 In terms of accuracy and scanning depth, the mea-
surement result can be inferior in case of unfavoura-
ble surface quality of the base material.
The measuring tool can be clearly identified with the serial
number 8 on the type plate.
Bosch Power Tools
Assembly

Inserting/Replacing the Batteries

To open the battery lid 4, press the latch 5 in the direction of
the arrow and remove the battery lid. Insert the batteries/re-
chargeable batteries. When inserting, pay attention to the
correct polarity according to the representation on the inside
of the battery compartment.
The battery indicator b in the upper status line on the display
16 indicates the charge condition of the batteries/rechargea-
ble batteries.
Note: Pay attention to the changing battery symbol so that
D-tect 150
the batteries/rechargeable batteries are replaced in time.
3 601 K10 005
Please change batteries
2)
±5 mm
2)
±5 mm
2)
4 cm
possible. Change the batteries/rechargeable batteries.
–10...+50 °C
To remove the batteries/rechargeable batteries, press on the
–20...+70 °C
rear end of a battery as indicated in the figure on the battery
4 x 1.5 V LR06 (AA)
lid ( ). The front end of the battery/rechargeable battery is
4 x 1.2 V HR06 (AA)
released from the battery compartment ( ), so that the bat-
tery/rechargeable battery can easily be removed.
Always replace all batteries/rechargeable batteries at the
5 h
same time. Do not use different brands or types of batter-
ies/rechargeable batteries together.
7 h
 Remove the batteries/rechargeable batteries from the
IP 54 (dust and
measuring tool when not using it for longer periods.
splash water
When storing for longer periods, the batteries/rechargea-
protected)
ble batteries can corrode and self-discharge.
22 x 9.7 x 12 cm
Operation
0.65 kg
 Protect the measuring tool against moisture and direct
sun light.
 Do not subject the measuring tool to extreme tempera-
tures or variations in temperature. In case of large var-
iations in temperature, allow the measuring tool to ad-
just to the ambient temperature before switching it on.
In case of extreme temperatures or variations in tempera-
ture, the accuracy of the measuring tool and the display in-
dication can be impaired.
 Do not attach any stickers or name-plates to the sensor
area 9 on the back of the measuring tool. Especially met-
al name-plates affect the measuring results.
 Use or operation of transmitting systems, such as
WLAN, UMTS, radar, transmitter masts or microwaves,
in the close proximity can influence the measuring
function.
 The measuring values can be impaired through certain
ambient conditions. These include, e.g. the proximity
of devices that produce strong electric, magnetic or
electromagnetic fields, moisture, metallic building ma-
terials, foil-laminated insulation materials or conduc-
English | 15
When the "Please change
batteries" warning indica-
tion is indicated on the dis-
play 16, the settings are
saved and the measuring tool
switches off automatically.
Measurements are no longer