As you can see, the responses are of the form:
PM parameter number, value.
You can also read the values of the parameters individually using commands of the form
? PM X
where X identifies the parameter. Each parameter is identified by a parameter number corresponding to a
parameter name. These are summarized for your reference in
For example, to verify the value of the ascent sampling period, send the command:
? PM 7
PROVBIO-B will respond:
<PM7
10>
]
where 10 is the sampling period in ascent (refer to

5.6. Float check up

Float check up may be performed thanks ti !C command.
PROVBIO-B will respond:
<C CPU:OK V: OK BAT:OK RES:OK SENSOR:OK CRC_FLASH:OK (
OPTIQUE:OK IRIDIUM:OK>+CR+LF

5.7. How to Check the Time

Connect the PC to the float using the RS232 interface cable (refer to section
Ask PROVBIO-B to display the time stored in its internal clock by sending the command:
? TI
(Do this by typing the characters ? TI followed by the Enter key.
PROVBIO-B will respond:
<TI a2008 m4 j12 h14 m41 s41>
]
with the time in the format YYYY/MM/DD hh:mm:ss

5.8. Acceptance Tests

Immediately upon receipt of the PROVBIO-B float, you should test it to confirm that it is complete, correctly
configured and has not been damaged in shipment. If your PROVBIO-B float fails any of the following tests,
you should contact KANNAD.

5.8.1. Inventory

The following things should have arrived with your PROVBIO-B float:
This user's manual.
RS232 interface cable (if not previously supplied).
Test sheet.
NOTE:
Disassembly of the float voids the warranty.
Check that all of the above items are present. If any are missing, contact KANNAD.

5.8.2. Physical Inspection

Upon the opening of the transport casing, visually inspect the float's general condition:
Inspect the transport container for dents, damage, signs of impact or other signs that the float has been
mishandled during shipping.
Inspect the CTD sensor, optical sensor, antenna, hull, housing around the lower bladder, and the test port
for dents or any other signs of damage (refer to
NOTE:
Ensure the magnet is in place against the hull.
PROVBIO-B
Table 1: page
Table 1: page
page 2
for the locations of these components).
PAGE : 14 / 72
DATE : 26/03/2008
INDEX : A
REF. : DOC08018
9.
9).
Calculated Checksum
5.3. page
12).
)