4.6.
Overview of all codes
Following codes can be changed in the installer menu:
1st
2nd
code
code
Description
Readout codes
‚

4
Calibration of
+
temperature
sensor inside
the thermostat.
Actual
temperature +
offset are
displayed. The
J
appears when
the offset
deviates from 0.

7
Calibration of
+
external
temperature
sensor. Actual
temperature +
offset are
displayed. The
J
appears when
the offset
deviates from 0.

Calibration of
humidity sensor.
Actual humidity
+ offset are
displayed. The
J
appears when
the offset
deviates from 0.
RKRTR + EKRTETS
Room thermostat
4PW56107-1
Default
Offset = 0 Offset:
symbol
Offset = 0 Offset:
symbol
Offset = 0 Offset: 10% 1%
symbol
Range
Step
0.1°C
–5°C~5°C
Offset:
0.2°F
–9°F~9°F
0.1°C
–5°C~5°C
Offset:
0.2°F
–9°F~9°F