Faults - Thermopatch NL-15 R MAMMOTH Manuel Utilisateur

Masquer les pouces Voir aussi pour NL-15 R MAMMOTH:
Table des Matières

Publicité

10. Faults

Fault
Heating plate does not
heat up.
Heating plate is too hot or
too cold.
Machine opens too soon
Machine does not close
Insufficient adhesion
of patches, label tapes,
labels or fixing of the
transfers
The colour of the textile
penetrates the transfer
V. 3.0 ENG
Jan2014
Manual NL-15 R / SQR V.4.2 traduction de la version originale NL-15 R / SQR V.4.2 NL Janvier 2021
If a problem should occur, please consult the list below; if
the problem you are facing cannot be solved by yourselves
contact your supplier.
Possible cause
1. ON/OFF switch is not set to ON
2. Machine is not connected to the
electricity grid
3. Electronics not connected to the
machine
4. Temperature sensor defective
5. Electronics wrongly set
6. Electronics defective
7. Heating element defective
1. Check the temperature settings
1. Check the sealing time settings
1. Pressure or temperature is not
correct
2. Swivel arm is not in final position
3. Contact switch is not correctly
positioned
1. Press time too short
2. Incorrect pressure
3. Heating plate too cold
4. Press pad of lower plate worn out
5. Teflon below heating plate dirty or
worn
1. Temperature set too high
2. Pressure set too high
3. Sealing time set too long
Oplossing
Check
Check
Check
Check
Check
Check
Check and replace when
necessary
Correct
Correct
Check
Bring swivelling arm back
to end position
Correct
Increase time settings
by 2 seconds and check
results
Set pressure correctly
with knob and check
results
Check temperature
Replace
Clean with soft cloth or
replace
Follow heat sealing in-
structions carefully
39

Publicité