Faults - Thermopatch NL-15 R MAMMOTH Manuel Utilisateur

Masquer les pouces Voir aussi pour NL-15 R MAMMOTH:
Table des Matières

Publicité

10. Faults

If a problem should occur, please consult the list below; if the problem you are facing cannot be solved by
yourselves contact your supplier.
Fault
Heating plate does not heat up.
Heating plate is too hot or too cold.
Machine opens too soon
Machine does not close
Insufficient adhesion of patches, label
tapes, labels or fixing of the
transfers
The colour of the textile penetrates
the transfer
RETOUR AU CONTENU
Pour plus d'informations sur nos produits et savoir comment nous contacter, visitez thermopatch.com
Possible cause
1. ON/OFF switch is not set to ON
2. Machine is not connected to the
electricity grid
3. Electronics not connected to the
machine
4. Temperature sensor defective
5. Electronics wrongly set
6. Electronics defective
7. Heating element defective
1. Check the temperature settings
1. Check the sealing time settings
1. Pressure or temperature is not correct
2. Swivel arm is not in final position
3. Contact switch is not correctly positioned
1. Press time too short
2. Incorrect pressure
3. Heating plate too cold
4. Press pad of lower plate worn out
5. Teflon below heating plate dirty or
worn
1. Temperature set too high
2. Pressure set too high
3. Sealing time set too long
Solutions
Check
Check
Check
Check
Check
Check
Check and replace when necessary
Correct
Correct
Check
Bring swivelling arm back to end posi-
tion
Correct
Increase time settings
by 2 seconds and check
results
Set pressure correctly
with knob and check
results
Check temperature
Replace
Clean with soft cloth or
replace
Follow heat sealing instructions care-
fully
37 37

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Nl-15 sqr mammoth

Table des Matières