Causes Of Faults; Information Message; Error Messages - FEIG Electronic MWD BPC-H Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
8

Causes of faults

The following points can be the causes of faults for incorrect reactions of the motion detector:
moving parts in the sector,
-
vibrations which are transferred to the device via the mounting bracket,
-
electrical faults via the connection cable,
-
electric fields (radio),
-
fluorescent or gas discharge lamps in the detection area,
-
reflection of the radar rays on conductive floors or walls.
-

8.1 Information message

Table 10: Information message
No.
Description
I.6A5
New or unconfigured motion detector on the CAN bus

8.2 Error messages

For detailed information on the handling of fault messages, please refer to the assembly instructions for the
respective door controller.
Table 11: Malfunctions
No.
Description
A motion detector is
F.6A6
parameterized at several
positions
More than four motion
F.6A7
detectors are connected
Break in communication
F.6AA
motion detector 1
Break in communication
F.6AB
motion detector 2
Break in communication
F.6AC
motion detector 3
Break in communication
F.6AD
motion detector 4
FEIG ELECTRONIC GmbH
Contents
Behavior/possible
cause
All connected motion
detectors indicate
normal operational
readiness.
Controller activates
input for the presence
monitoring.
The yellow LED is
turned off and the
red LED flashes
4x/second
Bus connection is
incorrect
47/74
MWD BPC-H / MWD BPC-HU
Behavior/possible cause
Controller activates input for the
presence monitoring, if it is a laser
scanner.
Remedy
Check configuration and redefine the
position of the motion detector.
Verify that a maximum of four motion
detectors are connected and reduce if
necessary.
Check bus connection
If the bus connection is ok, change
the motion detector
Check the terminating resistor
MWD_BPC-H-HU_ver4_Manual_rev0_mul

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mwd bpc-hu

Table des Matières