5.4.3 Set position, read out serial number, activate convenience profiles
Each connected motion detector must be assigned to a position in the door controller (see Figure 7, MWD
BPC 1-4). This is done via the parameter L.601, L.701, L.801 or L.901 and using the serial number of the
motion detector. When selecting the parameter, the last four digits of the serial number of the motion detector
are displayed and both LEDs of the selected motion detector flash.
If no motion detector is assigned to parameter L.601, L.701, L.801 or L.901, the respective parameters must
be set to "0". All assigned motion detectors in the door controller are automatically activated (L.602, L.702,
L.802 or L.902 set to "1").
Table 4: Parameter for position assignment
1
L.601
L.660
L.701
L.760
2
L.801
L.860
3
L.901
L.960
4
FEIG ELECTRONIC GmbH
Contents
L.662
L.61F
L.762
L.71F
L.862
L.81F
L.962
L.91F
39/74
Outside
MWD BPC 2
L.701
L.801
MWD BPC 3
Inside
Outside
Left/Middle
Right
L.601
L.701
Figure 7: Example for position assignment with motion
detectors
MWD_BPC-H-HU_ver4_Manual_rev0_mul
MWD BPC-H / MWD BPC-HU
MWD BPC 1
L.601
Door
L.901
MWD BPC 4
Inside
Left/Middle
Right
L.801
L.901