General Recommendations - deville C07836 Notice D'installation Et D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Place the connecting pipe
-
Connection to the appliance :
Position the appliance in the fireplace (see § 5.8) and fit the pipe into the outlet of the appliance (Fig. 9).
-
NOTA : The connecting pipe
-
If there is not enough place over the appliance, several solutions can be used to fit the pipe.
.
Pre-insert in the pipe, about 10 cm from the bottom, a pin by which the pipe can be held, with your hand
inside the appliance. The pin can stay where it is without any effect on performance (Fig. 9).
.
It is also possible, once all parts taken out from the inside of the unit, to remove the connecting nozzle (6
screws HM6). The pipe can then be introduced through the inside of the appliance.
The ventilation of the hood will be realized as for a new fireplace (refer to § 5.7.1).
5.8 PREPARATION AND FITTING OF THE APPLIANCE WITHIN THE FIREPLACE

5.8.1 General recommendations

To reduce the weight of the appliance, and make its installation easier, remove the deflector, the other cast iron
parts placed inside the unit, and also the doors (also remove the polystyrene wedge holding the deflector).
5.8.2 Use of the lateral squares
They make the embedding of the appliance within the fireplace easier.
Before casing the insert, screw on the sides of the unit the 4 screws supplied (there are 2 holes on each side).
Stop the screwing in order to be able to fit easily, without too much play, the side squares on the screws after
having put the appliance in its place.
Once the appliance is installed, slide the 2 squares, cut-out parts facing screws, then take squares down up to
floor (refer to Fig. 11 and 12).
5.8.3 Fitting of the upper hot air grille
Remove the draught damper from the top (Fig. 22) ; draw out the control stem, flap, crossbar, spring and stem
ring.
Introduce the control stem through the hot air grille (between 2
reassemble successively the ring, spring and crossbar.
Adjust the whole on the appliance and fix the grille with 2 of the screws supplied in the bag (use the 2 holes
placed at the bottom of the grille).
Refit the flap, tighten its fixing screw (vertical key for vertical flap).
5.8.4 Hot air supply
Hot air can be supplied in the adjacent rooms :
Remove the 4 pre-cut obturators on the top of the appliance : drill (using a Ø 6 bit) through the 3 existing
-
holes (Ø 2). Put the Ø 125 hot air outlets
-
Slightly unscrew the 2 fixing screws of the hot air grille ; then slide the obturating plate
and the unit itself. Use the 2 remaining screws from the bag to fix the plate on the appliance (Fig. 13). Then
tighten the 2 fixing screws of the hot air grille.
Ensure a thermal protection of the hot air flues (minimum 16 cm between hot air duct and combustible
-
materials), and use insulated ducts. The selected materials should be highly heatproof (classification MO).
WARNING : The hot air ducts should not be in contact with any parts of the smoke evacuation circuit. Even
more important, the hot air ducts should in no case run through the smoke pipe.
Go from the appliance with vertical ducts as high as possible in order to privilege circulation by convection,
-
limit the lengths of horizontal ducts and the number of bends.
in the sealed flange
and the flange
should be in stainless steel, minimum thickness 0,4 mm.
supplied with the appliance in place of the obturators (Fig. 13).
22
and fix it in the high position.
nd
rd
and 3
bar from the top of the grille), then
between the grille

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

C07867C07887

Table des Matières