Definition; Nominal Heating Output - deville C07836 Notice D'installation Et D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
You are advised to read carefully and in full the information provided in order to get the best
performance - and the most satisfaction - out of your DEVILLE insert.
Failure to comply with the assembly, installation and operating instructions places all responsibility
THIS APPLIANCE MUST BE INSTALLED IN COMPLIANCE WITH CURRENT D.T.U. SPECIFICATIONS.
All local, national and European regulations must be respected when using this appliance.
INSTALLATION MUST BE MADE BY A QUALIFIED TRADESMAN.

1 - DEFINITION

This turbo insert complies with French Standard NF EN 13229.
This insert hearth is a continuous heating appliance with an on-grid combustion, using wood, with a semi-closed
combustion chamber.
It is meant to be installed in a new fireplace to be built, or in an existing hearth.
Note the serial number written on the label sticked on the unit and on the waranty certificate. Write this number in the
following case :
This serial number will be necessary to identify the unit in case of spare parts requirements.
Device in accordance with the Electromagnetic Accountancy Directive 89/336/EEC altered by the Directive 93/68/EEC.

2 - NOMINAL HEATING OUTPUT

Nominal output
11 kW
-
Nominal heating output in continuous use : 11 kW.
. Obtained with a draught of 12 Pa, for 1 hour burning time, with a 3,7 kg load of hard unsplit wood (oak,
hornbeam...), i.e. approx. 3 logs diameter 7 cm.
. To maintain this value, reload on to a bed of embers of about 500 g, or 4 cm thick.
. The above value is the average value obtained during the 1-hour test, draught damper (pipe key) open,
thermostat set on 8.
Slow burning :
-
Obtained with a 6 Pa draught, pipe key closed, thermostat set on 0.
Reload on a bed of embers of about 0,3 kg (3 cm thick).
Burning time over 3 hours with an unsplit log of hard wood of about 3,7 kg.
Burning time over 10 hours with one or two unsplit logs (choose big diameter) of hard wood, total
weight 11 kg.
The use of the appliance in normal working conditions allows to reach a maximal output which must not be
-
exceeded for safety reasons.
-
The maximum load of wood is 12 kg.
Ventilator output : 150 m
upon the person(s) concerned.
The appliance must not be modified.
Draught
12 Pa
3
/h.
Flue gas mass flow
11,86 g/s
17
Smoke temperature
317°C

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

C07867C07887

Table des Matières