Find an escape route to an emergency exit. If this is not possible, wait for the
rescue teams to arrive! Knock on walls or stand at a window so that the
rescuers can find you.
5
Maintenance
The maximum life time of the filtering escape hood is 8 years from the date of
manufacture. After the filter has been replaced once, the life time of the escape
hood is extended by a further 8 years. After 16 years have passed dispose of the
escape hood.
The escape hood must be maintained by competent personnel only.
Replace the filter of an unused escape hood if
the plugs of the filter have been opened.
the seal is damaged.
the expiry date shown on the packaging has been exceeded.
8 years have passed.
Use the filter replacement kit; see the corresponding assembly instructions.
The Dräger PARAT 5550 has a one-time maximum life time of 8 years.
Afterwards, one filter replacement by the service of Dräger is possible.
5.1
Cleaning
For information on suitable cleaning products and disinfectants and their
specifications, see document 9100081 at 
www.draeger.com/IFU
Clean the bag for the Dräger PARAT 5550 with a mild cleaning agent in the event
of contamination. Pre-treat any heavy contamination by cleaning the bag
1)
manually
.
1. Remove the foil pouch from the bag before cleaning.
2. Prepare a cleaning solution consisting of water and a cleaning agent.
3. Clean the bag using a soft cloth and the cleaning solution.
4. Then rinse thoroughly under running water. 
Ensure that the bag is completely dry after the cleaning process.
5. Only then can the Dräger PARAT 5550, packaged in the foil pouch, be stored
in the bag.
6
Storage
Store the escape hood in its packaging in a cool and dry place. Avoid direct
sunlight and temperatures below -20
7
Disposal
Dispose of the filter and escape hood in accordance with the applicable local
waste disposal regulations.
1)
Not tested within the framework of EU prototype tests.
Dräger PARAT 4000/5000/7000
o
C and above +55
Maintenance
o
C.