Technical Data - Tecsis S2350 Instructions De Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9. Technical data

9. Technical data
Configuration
Pressure connection
Setting
Materials
• Measuring component
• Pressure connection
• Housing
Load change
Auxiliary power
Power consumption
Outputs
• S2400, S2350
• S2410, S2350
• S2420
Switch outputs
• Quantity
• Function
• Switching current
• Setting
- Switching point
- Reset point
Betriebsanleitung / Operating manual / Instructions de service / Instrucciones de uso
Overpressure, positive or negative
G 1/4 DIN 3852-E (standard)
Menu-guided programming using control buttons
< 100 bar ceramic with NBR seal
> 100 bar stainless steel
S2400/S2410/S2420: stainless steel,
S2350/S2360: brass, nickelplated
S2400/S2410/S2420: stainless steel,
S2350/S2360: aluminium
> 10 million pressure cycles
12... 30 VDC
< 50 mA, without load current
2 switch outputs, programmable
1 programmable switch output and 1 analogue output,
programmable, scaling 20...100% of final value
2 programmable switch output and 1 analogue output,
programmable, scaling 20...100% of final value
1 or 2 x switch to N or P potential (Model S2420 = P potential)
Normally open contact (NO) or normally closed contact (NC), programmable
max. 0.5 A
Via display with control buttons
1 to 100% of final value
0...99% of final value (but lower than switching point)
GB
35

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

S2360S2400S2410S2420Sc350Sc360 ... Afficher tout