ELECTRICAL CONNECTION
WARNING:
Link up all N.C. contacts (if not used) by means of jumpers.
The terminal bearing the same number are equivalent.
The given operating and performance features can only be guaranteed with the use of DITEC
accessories and safety devices.
1.1 Controls
CONTROL
1
5 N.O. STEP BY STEP
1
6 N.C. STOPPING SAFETY CONTACT It stops or prevents the any operation.
1
8 N.C. REVERSAL SAFETY CONTACT Reverses the direction of movement during the closing
1
9 N.C. STOP
RADIO / OPEN
STEP BY STEP

1.2 Outputs and accessories

Output
24V = / 0.3 A (nominal)
1
+
0
-
24V = / 30 W max.
0
14
24V = / 1.2 A max.
0
15
1
13
24V = / 3 W max.
Motor
connection
BAT
DITEC S.p.A. - IP1586 - D2H
FUNCTION
Value
Accessories power supply. Output for power external accessories
0.5 A (peak)
including the door-open signal lamp. Electronically-protected exit.
Flashing light (LAMPH). It is activated during the opening and closing
movements. During an automatic closing procedure the blinking phase
begins 3 s before the time set on TC expires; if TC is set to less than 3 s, the
preliminary blinking phase continues throughout the entire standstill time.
Protected exit with fuse F2.
Electric lock. In connection with an electric lock having 12V the resistance
of 8.2 Ohm/5 W is connected in series. It is activated at the beginning of
every opening movement. When DIP 3 = ON, the release can be activated.
Protected exit with fuse F2.
Light „Gate open". Activates a light that goes out only when the gate is
closed.
When there are double-leaf gates, connect the motors according to Fig.
1. Note: Depending on the direction of opening of the leaves of the gate,
the polarity of the motor may have to be reversed.
When there are single-leaf gates, bridge OM has to be interrupted and
the motor should be connected according to Fig. 2. Note: If it is neces-
sary to lengthen the motor cable, use 2x1.5 mm² up to a length of 15 m;
then increase the cross-section proportionally to the distance.
This connection is provided for connecting an optional emergency battery
(BATK1, equipped with a control circuit and charging device) to ensure
that the opening system functions in the event of a power failure.
DESCRIPTION
When DIP1 = OFF sequence:"Open-Stop-Close-Open".
Warning: if the automatic closure is enabled, the stop is
not permanent but lasts for the time set by means of TC.
When DIP1 = ON and automatic closing is activated, con-
tact 1-5 = "Open".
When DIP1 = ON and automatic closing is deactivated,
contact 1-5 executes the opposite movement of the one
that was executed prior to stopping when the gate is stand-
ing still. Note: with permanent contact 1-5, the automatic
closing is disabled until the contact reopens.
maneuver (opens the gate again). When the gate is
standing still and bridge SO is closed, every movement
– both opening and closing – is prevented. When the
gate is standing still and bridge SO is interrupted, only
the closing maneuver is prevented.
With the 1-9 contact, the gate stops or stays stopped and
automatic closing is disabled.
It has the same function as contact 1-5.