Code
QR code
QR code
QR code
QR code
QR code
QR code
Tab. 8.7:
Output
Parameter Settings
Notification of read failure
enable
disable
Output result with AIM ID
AIM ID in prefix
No AIM ID in prefix
Tab. 8.8:
Control options
Option
Trigger duration
Decode area
Leuze electronic
Parameter Settings
Settings of register 2B are bitwise OR-connected. Example :
• Command (2B)11 enables Standard and Mirror QR Code decoding and disables
Inverse, Micro, and Model 1 QR Code decoding.
Standard decoding
enable
disable
Inverse decoding
enable
disable
Micro decoding
enable
disable
Mirror decoding
enable
disable
Model 1 decoding
enable
disable
Parameter Settings
Trigger duration [ms]
Read in both fields
Read in high-density field
Read in wide-angle field
Command-Data
(2B)01
(50)00
(2B)02
(2B)00
(2B)04
(2B)00
(2B)10
(2B)00
(2B)20
(2B)00
Command-Data
(55)1
(55)0
(ED)1
(ED)0
Command-Data
(35)0 ... 7FFFFFFF
(39)3
(39)5
(39)6